4. INSTALLING OPTIONAL EQUIPMENT
Setting method 2: by make and model of gyrocompass
Maker | Models | Specification | SW | SW | SW | SW | SW | SW | SW | SW | SW | SW | SW | JP1 | JP2 | JP3 | JP4 | JP5 |
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Anschutz | Standard 2,3 | AC synchronous | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | ON | OFF | #1, | #2 | #2 | #1 | # |
|
| 50/60Hz |
|
|
|
|
|
|
|
|
|
|
| #2,#3 |
|
|
|
|
|
| Rotor voltage: 50/60V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Stator voltage: 22V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 360x |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Standard 4,6 | AC synchronous | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | #1, | #2 | #1 | #1 | # |
|
| 50/60Hz |
|
|
|
|
|
|
|
|
|
|
| #2,#3 |
|
|
|
|
|
| Rotor voltage: 50/60V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Stator voltage: 90V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 360x |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Standard 20 | DC step | ON | OFF | OFF | ON | OFF | OFF | ON | ON | - | ON | OFF | #4, | #2 | - | #2 | # |
|
| 35V 180x |
|
|
|
|
|
|
|
|
|
|
| #5,#6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Yokogawa | AC synchronous | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | ON | OFF | #1, | #2 | #2 | #1 | # | |
Navtec | 50/60Hz |
|
|
|
|
|
|
|
|
|
|
| #2,#3 |
|
|
|
| |
(Plaith |
| Rotor voltage: 50/60V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
type) |
| Stator voltage: 22V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 360x |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DC step | ON | OFF | OFF | ON | OFF | OFF | ON | ON | - | ON | OFF | Remo- | #2 | - | * | * | |
|
| 24V 180x | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ve |
|
| |||
|
| COM(+), |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DC synchronous 360x | OFF | OFF | OFF | OFF | OFF | OFF | ON | ON | - | ON | OFF | Remo- | #2 | - | * | * | |
| 300X/500 |
|
|
|
|
|
|
|
|
|
|
|
| ve |
|
| ||
|
| DC step | ON | OFF | OFF | ON | OFF | OFF | ON | ON | - | ON | OFF | #4, | #2 | - | #2 | #2 |
|
| 35V 180x |
|
|
|
|
|
|
|
|
|
|
| #5,#6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| AC synchronous | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | #1, | #1 | #1 | #1 | #1 | |
| 300 | 50/60Hz |
|
|
|
|
|
|
|
|
|
|
| #2,#3 |
|
|
|
|
| Rotor voltage: 100V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Stator voltage: 90V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 360x |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| step | ON | OFF | OFF | ON | OFF | OFF | ON | ON | - | ON | OFF | Remo- | #2 | - | * | * | |
| See note below. | 35V 180x |
|
|
|
|
|
|
|
|
|
|
| ve |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Plaith | NAVGAT II/III | AC synchronous | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | #1, | #2 | #2 | #1 | #1 |
|
| 50/60Hz |
|
|
|
|
|
|
|
|
|
|
| #2,#3 |
|
|
|
|
|
| Rotor voltage: 50/60V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Stator voltage: 68V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 360x |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Tokimec | AC synchronous | ON | ON | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | #1, | #1 | #1 | #1 | #1 | |
(Sperry | 50/60Hz |
|
|
|
|
|
|
|
|
|
|
| #2,#3 |
|
|
|
| |
type) | 103/106K/107 | Rotor voltage: 100/110V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Stator voltage: 90V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 36x |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| AC synchronous | OFF | ON | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | #1, | #1 | #1 | #1 | #1 | |
| 50/60Hz |
|
|
|
|
|
|
|
|
|
|
| #2,#3 |
|
|
|
| |
| PR222R/2000 | Rotor voltage: 100/110V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| PR237L/H | Stator voltage: 22V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| GM 21 | 90x |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DC step | ON | OFF | OFF | ON | OFF | OFF | ON | ON | - | OFF | OFF | #4, | #2 | - | #1 | #1 | |
| 70V 180x |
|
|
|
|
|
|
|
|
|
|
| #5,#6 |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| DC step | ON | OFF | OFF | OFF | ON | OFF | OFF | OFF | - | OFF | OFF | #4, | #2 | - | #1 | #1 | |
|
| 70V 180x |
|
|
|
|
|
|
|
|
|
|
| #5,#6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| DC step | ON | OFF | OFF | ON | OFF | OFF | ON | ON | - | OFF | OFF | #4, | #2 | - | #1 | #1 | |
| 70V 180x |
|
|
|
|
|
|
|
|
|
|
| #5,#6 |
|
|
|
| |
| 140, | COM(+), |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| /203 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DC step | ON | OFF | OFF | ON | OFF | OFF | ON | ON | - | ON | OFF | #4, | #2 | - | #2 | #2 | |
|
| 24V 180x |
|
|
|
|
|
|
|
|
|
|
| #5,#6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| AC synchronous | OFF | ON | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | #1, | #1 | #1 | #1 | #1 | |
|
| 50/60Hz |
|
|
|
|
|
|
|
|
|
|
| #2,#3 |
|
|
|
|
|
| Rotor voltage: 100V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Stator voltage: 90V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 90x |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DC step | ON | OFF | OFF | ON | OFF | OFF | ON | ON | - | ON | OFF | #4, | #2 | - | #2 | #2 | |
| 35V 180x |
|
|
|
|
|
|
|
|
|
|
| #5,#6 |
|
|
|
| |
Kawasaki | AC synchronous | OFF | ON | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | #1, | #1 | #1 | #1 | #1 | |
|
| 50/60Hz |
|
|
|
|
|
|
|
|
|
|
| #2,#3 |
|
|
|
|
|
| Rotor voltage: 100/110V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Stator voltage: 90V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 90x |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Armabrown | DC step | ON | OFF | OFF | ON | OFF | OFF | ON | ON | - | OFF | OFF | #4, | #2 | - | #1 | #1 | |
| SERIES1351, | 50V 180x |
|
|
|
|
|
|
|
|
|
|
| #5,#6 |
|
|
|
|
| COM(+), |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Robertson | DC step | ON | OFF | OFF | ON | OFF | OFF | ON | ON | - | ON | OFF | #4, | #2 | - | #2 | #2 | |
|
| 35V 180x |
|
|
|
|
|
|
|
|
|
|
| #5,#6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*: Set JP4 and JP5 according to the voltage of the external power supply.
Note: If