Hitachi MK-96RD647-01 manual Allocater = a, Bytes, 23477, 9077

Models: MK-96RD647-01

1 226
Download 226 pages 34.71 Kb
Page 117
Image 117

OPEN-8

5818

5818

5818

 

9959

(min 9996*n-7,

 

 

 

 

 

 

65534)

 

 

 

 

 

 

 

OPEN-9

5818

5818

5818

10009

(min 10016*n-7,

 

 

 

 

 

 

65534)

 

 

 

 

 

 

 

OPEN-E

not

5818

5818

19752

(min 19759*n-7,

 

supported

 

 

 

 

65534)

 

 

 

 

 

 

 

OPEN-L

not

5818

5818

49429

(min 49439*n-7,

 

supported

 

 

 

 

65534)

 

 

 

 

 

 

 

OPEN-V

not

not supported

not supported

65534

(min(Vc*n*128/

 

supported

 

 

 

 

96-7,65534)

 

 

 

 

 

 

(see Note 4)

 

 

 

 

 

 

 

Note 2: XX = 1 or 2; YY,x = number; ZZ<2x

Note 3: For Solaris, the data cylinder must be less than or equal to 32767. When using a LUSE volume, the geometry parameter is different, so the number of cylinders should be calculated as follows:

Cylinder (specified to FAL formatting) <= (A*B*C) / (15*96) – 5

A:Head (Geometry parameter)

B:Block/Track (Geometry parameter)

C:cylinder (Geometry parameter)

Note 4: Vc = OPEN-V cylinder value (MAX.:49160 cylinders using FAL)

The FMT utility can be used on standard-size OPEN-xvolumes and on Virtual LVI/LUN (VIR) volumes.

Note: The VIR OPEN-xdevices can also be called custom volume size (CVS) devices (e.g., OPEN-3-CVS). When formatting a VIR OPEN-xLU, use the number of cylinders defined for VIR minus seven (e.g., use 993 cylinders for a VIR device defined with 1000 cylinders). The cylinder size is: one cylinder = 15 tracks, one track = 96 sub-blocks, one sub-block = 512 bytes. Table 3-9shows the relation between block length and write available capacity per track. The actual data capacity per cylinder = (write available capacity per track) (15 tracks).

Table 4-2 Relation between Block Length and Write Available Capacity per Track

Block Length by

Write Available

Block Length by

Write Available

Block Length by

Write Available

Allocater = (A)

Data per Track

Allocater = (A)

Data Per Track

Allocater = (A)

Data Per Track

(Bytes)

(Bytes)

(Bytes)

(Bytes)

(Bytes)

(Bytes)

 

 

 

 

 

 

23477 - 32760

(A) 1

1589 - 1684

(A) 22

565 - 596

(A) 44

 

 

 

 

 

 

15477 - 23476

(A) 2

1493 - 1588

(A) 23

533 - 564

(A) 45

 

 

 

 

 

 

11477 - 15476

(A) 3

1397 - 1492

(A) 24

501 - 532

(A) 46

 

 

 

 

 

 

9077 - 11476

(A) 4

1333 - 1396

(A) 25

469 - 500

(A) 47

 

 

 

 

 

 

 

Using the Cross-Os File Exchange Software

 

4-23

Hitachi USP V Cross-OS File Exchange User’s Guide