8.The FCU main panel displays the first/next parameter set in the specified FCU parameter definition file. If you want to perform this FX operation, click Execute. If not:

a)You can load the next parameter set using the Parameter-Load-Nextcommand ().

b)You can delete the current parameter set from the FCU parameter

definition file using the Parameter-Deletecommand (). The next parameter set loads automatically.

c)You can modify the current parameter set as follows: Change the FCU parameters as needed, and then use the Parameter-Save-Replace

command () to replace the previously loaded parameter set with the new parameter set.

d)You can add a new parameter set as follows: Change the FCU parameters

as needed, and use the Parameter-Save-Insertcommand () to insert the new parameter set below the current parameter set.

e)If the Continuous operation option is selected, you can open the Error information panel before starting the operations to monitor the FCU processing. Move the Error information panel so that it does not overlap the FCU main panel.

9.When the desired FX operation is displayed, click Execute to start the operation. (If the Execute button is not enabled, you have not saved the current parameter set.) If the Continuous operation option was selected, FCU will process all operations from the current line to the end of the file and then self-terminate. The error information for these operations is placed in the most recent .log file(s) in the current directory (e.g., mto.log).

WARNING: In some early versions of FCU for Windows 2000/2003/Windows NT systems, FCU may overwrite existing Windows 2000/2003/Windows NT systems target files without requesting confirmation.

10.If you started an FXmto operation and the target file already exists, FCU requests overwrite confirmation. Click OK to overwrite the target file, or click Cancel to cancel the operation.

11.When FCU starts the operation, the Execute panel opens and displays the progress of the operation. To cancel the operation in progress, select Cancel.

Note: The Execute dialog panel will not appear when the mainframe OS is VSE.

12.When the operation is complete, the Execute panel displays the result. If an error occurred, the Error information panel opens automatically to display the error. See Error Codes and Messages for further information on errors.