If FCU for UNIX reports an error, use the Help-Errorcommand to view the most recent error. Table 7-3lists and describes the FCU error codes for UNIX and provides instructions for resolving each error condition. In Table 7-3,the error codes marked by an asterisk (*) may also be reported when I/O access contention for the FX volume occurs between the z/OS and open-system hosts. If the cause of the error cannot be identified as described in Table 7-3,check for any illegal I/O contention for the FX volume.

Note: Error codes with a negative value are FCU errors. Error codes with a positive value are system errors. UNIX system error codes are defined in the standard error file errno.h.

Note: The error codes with “(C)” in the “Error code” cell in Table 7-3are generated only when using with FX Code Converter. For details, please see the Hitachi Lightning 9900 V Series FX Code Converter User’s Guide (MK- 93RD152).

Table 7-3 FCU Error Codes for UNIX

Error

 

Error Message and Description

 

Recommended Action(s)

Code

 

 

 

 

 

 

 

 

 

-100

 

No parameter file

 

If you specified the parameter definition file using the

 

 

The FCU parameter definition file

 

[param] option, make sure that the specified file exists and

 

 

 

the name is correct.

 

 

could not be found.

 

 

 

 

If you did not specify the [param] option when you started FCU, make sure

 

 

 

 

 

 

 

 

that the default parameter definition file exists (fcudata.param in the current

 

 

 

 

directory).

 

 

 

 

-101*

Parameter file: Open error

 

Display the system error code using the Help-Error

 

 

An error occurred when opening

 

command. Please refer to the OS user manual for

 

 

 

information on system errors.

 

 

the parameter definition file.

 

 

 

 

 

 

 

 

 

-102*

Parameter file: Read error

 

Display the system error code using the Help-Error

 

 

An error occurred when reading

 

command. Please refer to the OS user manual for

 

 

 

information on system errors.

 

 

the parameter definition file.

 

 

 

 

 

 

 

 

 

-103*

Parameter file: No valid data

 

Make sure that the FCU initiation parameters are entered

 

 

The parameters in the parameter

 

correctly in the parameter definition file.

 

 

definition file are not valid.

 

 

 

 

 

 

 

-107

 

Parameter file: CODE_CONV error

 

Make sure that the code conversion is specified as either EA

 

 

The code conversion specified in

 

or No.

 

 

 

 

 

 

the parameter definition file is not

 

 

 

 

valid.

 

 

 

 

 

 

 

-108

 

Parameter file: PADDING error

 

Make sure that the padding is specified as either Yes or No.

 

 

The padding option specified in

 

 

 

 

the parameter definition file is not

 

 

 

 

valid.

 

 

 

 

 

 

 