Hitachi MK-96RD647-01 manual 206, Padding parameter to No, RDW error Delimiter not, Parameters

Models: MK-96RD647-01

1 226
Download 226 pages 34.71 Kb
Page 200
Image 200

Error

 

Error Message and Description

 

Recommended Action(s)

Code

 

 

 

 

 

 

 

 

 

-206

 

RDW error: PADDING not supported

 

Padding cannot be processed when RDW=Yes. Change the

 

 

Padding is not specified as No

 

padding parameter to No.

 

 

 

 

 

 

when RDW=Yes.

 

 

 

 

 

 

 

-207

 

RDW error: DELIMITER not

 

Delimiters cannot be processed when RDW=Yes. Change

 

 

supported

 

the delimiter parameter to No.

 

 

Delimiter is not specified as No

 

 

 

 

when RDW=Yes.

 

 

 

 

 

 

-210

Parameter file: Comment line

 

If you specify Load, FCU will move to the next line. You can

 

 

This is a comment line in the

 

also replace the comment line with a valid parameter.

 

 

 

 

 

 

parameter file.

 

 

 

 

 

 

 

-220

 

Parameter: VSE select error

 

Make sure that the number of VSE parameters is correct and

 

 

The VSE parameter format is not

 

that a comma is used correctly to separate the VSE

 

 

 

parameters.

 

 

correct.

 

 

 

 

 

 

 

 

 

 

-221

 

Parameter: VSE record format error

 

Make sure that the record format is set to either one of

 

 

Record format in the VSE

 

F/FB/V/VB.

 

 

 

 

 

 

parameter is not correct.

 

 

 

 

 

 

 

-222

 

Parameter: VSE record length error

 

Make sure that the record length is set to the correct value

 

 

Record length in the VSE

 

within the extent allowed.

 

 

 

 

 

 

parameter is not correct.

 

 

 

 

 

 

 

-223

 

Parameter: VSE block length error

 

Make sure that the block length is set to the correct value

 

 

Block length in the VSE

 

within the extent allowed.

 

 

 

 

 

 

parameter is not correct.

 

 

 

 

 

 

 

-230

 

No code conv. table file: No code

 

Make sure that the code conversion table file name is correct

 

 

conv. table

 

and that the file exists. This error may also be reported if you

 

 

The code conversion table was

 

mix mainframe and OPEN-x devices in the same FX volume

 

 

 

definition file.

 

 

not found.

 

 

 

 

 

 

 

 

 

 

-231

 

Code conv. table: Open error

 

Refer to the OS user manuals for assistance.

 

 

The code conversion table could

 

 

 

 

not be opened.

 

 

 

 

 

 

 

-233

 

Code conv. table: Close error

 

Refer to the OS user manuals for assistance.

 

 

The code conversion table could

 

 

 

 

not be closed.

 

 

 

 

 

 

-234

Code conv. table: Get file data error

 

Check the contents of the file. Refer to the OS user manuals

 

 

The size of the code conversion

 

for assistance.

 

 

 

 

 

 

table could not be obtained.

 

 

 

 

 

 

 

-235

 

Code conv. table: File size error

 

Make sure that the size of the code conversion table is 256

 

 

The size of the code conv table is

 

bytes.

 

 

 

 

 

 

not correct.

 

 

 

 

 

 

 

-236

 

Code conv. table function: Invalid

 

Check the contents of the input file, especially the delimiters.

 

 

argument

 

 

 

 

No source data to be converted

 

 

 

 

was found.

 

 

 

 

 

 

 

-238

 

Code conv. table name: No data

 

If you do not specify EA or No for the code conversion

 

 

The file name of the code

 

option, make sure to specify the correct file name of your

 

 

 

code conversion table.

 

 

conversion table is not specified.

 

 

 

 

 

 

 

 

 

 

7-12Troubleshooting

Hitachi USP V Cross-OS File Exchange User’s Guide

Page 200
Image 200
Hitachi MK-96RD647-01 manual 206, Padding parameter to No, RDW error Delimiter not, Supported Delimiter parameter to No