Hitachi MK-96RD647-01 manual Performing File Transfer Operations Windows

Models: MK-96RD647-01

1 226
Download 226 pages 34.71 Kb
Page 145
Image 145

Performing File Transfer Operations (Windows)

To perform FX file transfer operations using the FCU GUI for Windows 2000/2003/Windows NT systems:

1.If you will be performing FXmto operations:

a)Make sure that the source datasets are located on the desired FX volume(s). If you will not be using an existing FCU parameter definition file, write down the VSN:dataset of the source dataset and the complete path and file name of the target file for each FXmto operation.

b)Verify that the FXmto target files do not already exist (or can be overwritten).

c)Vary the FXmto volume(s) and channel path(s) offline from the z/OS host.

2.If you will be performing FXotm operations:

a)Make sure that the source files are located on the desired FX volume(s). If you will not be using an existing FCU parameter definition file, write down the complete path and file name of the source file and the VSN:dataset of the target dataset for each FXotm operation.

b)Create and allocate the target datasets. This ensures that the target dataset is registered in the VTOC. Make sure to allocate enough space and to use the appropriate record format and record length for the data to be transferred.

c)Vary the FXotm volume(s) and channel path(s) offline from the z/OS host.

3.If you will be performing FXoto operations:

a)If you will not be using an existing FCU parameter def. file, write down the complete path and file name of the source and target files for each FXotm/mto operation.

b)Use the ALC utility to allocate the intermediate datasets on the FXoto volume(s). Make sure to allocate enough space and to use the appropriate record format and record length for the data to be transferred.

c)Verify that the FXoto target files do not already exist (or can be overwritten).

4.Make sure that the desired FX volume definition file (FXoto only, or FXmto and FXotm) is available for use by FCU (datasetmount.dat in current directory).

5.Start FCU (see section Starting the FCU GUI). If you want to specify any FCU options, start FCU from the DOS prompt.

Note: If you specify the -ncoption, FCU performs all specified operations continuously, then self-terminates and displays any error information at the DOS prompt.

Performing Cross-OS File Exchange Operations

5-19

Hitachi USP V Cross-OS File Exchange User’s Guide

Page 145
Image 145
Hitachi MK-96RD647-01 manual Performing File Transfer Operations Windows