Creating FXoto Volumes Using the FMT Utility

After the FAL/FCU software has been installed on the open-system host(s), you can format the FXoto volumes using the FX Formatter (FMT) utility. This enables you to allocate FXoto intermediate datasets. The FMT utility for UNIX is a UNIX command executed from the UNIX command line. The FMT utility for Windows 2000/2003/Windows NT is a GUI.

Note: FCU version 01-01-42 or later is required for the FMT utility.

The FX FMT utility defines the size of the OPEN-xvolume in cylinders. The maximum number of cylinders allowed by FMT is shown in Table 3-8.

Table 3-8 FMT Utility Values

Emulation Type

01-XX-47 or

01-XX-YY/ZZ not

01-XX-YY/ZZ

01-XX-YY/2x

01-XX-YY/2x

 

earlier

LUSE

LUSE

not LUSE

LUSE (Note 2)

 

(Note 2)

(Note 2)

(Note 2)

(Note 2)

n=number of

 

volumes

 

 

 

 

 

 

 

 

 

 

(Note 3)

 

 

 

 

 

 

OPEN-3

3331

3331

5818

3331

(min 3338*n-7,

 

 

 

 

 

65534)

 

 

 

 

 

 

OPEN-8

5818

5818

5818

9959

(min 9996*n-7,

 

 

 

 

 

65534)

 

 

 

 

 

 

OPEN-9

5818

5818

5818

10009

(min 10016*n-7,

 

 

 

 

 

65534)

 

 

 

 

 

 

OPEN-E

not

5818

5818

19752

(min 19759*n-7,

 

supported

 

 

 

65534)

 

 

 

 

 

 

OPEN-L

not

5818

5818

49429

(min 49439*n-7,

 

supported

 

 

 

65534)

 

 

 

 

 

 

OPEN-V

not

not supported

not supported

65534

(min(Vc*n*128/

 

supported

 

 

 

96-7,65534)

 

 

 

 

 

(see Note 4)

 

 

 

 

 

 

Note 2: XX = 1 or 2; YY,x = number; ZZ<2x

Note 3: For Solaris, the data cylinder must be less than or equal to 32767. When using a LUSE volume, the geometry parameter is different, so the number of cylinders should be calculated as follows:

Cylinder (specified to FAL formatting) <= (A*B*C) / (15*96) – 5

A:Head (Geometry parameter)

B:Block/Track (Geometry parameter)

C:cylinder (Geometry parameter)

Note 4: Vc = OPEN-V cylinder value (MAX.:49160 cylinders using FAL)

The FMT utility can be used on standard-size OPEN-xvolumes and on Virtual LVI/LUN (VIR) volumes.