Hitachi MK-96RD647-01 manual

Models: MK-96RD647-01

1 226
Download 226 pages 34.71 Kb
Page 91
Image 91

When record format = V or VB, 5 record length (block length 4).

8.Enter or select the block length in the Block length field. If block length = record length, select the Copy button to copy the record length into the Block length field.

When record format = F or FB, 1 block length 32760.

When record format = V or VB, 9 block length 32760.

9.When all parameters for the new dataset are correct, select the Start button.

10.When the allocate operation completes successfully, the Allocation complete message is displayed. If the allocate operation could not be started due to an error condition, the Allocate check error message is displayed. If the allocate operation did not complete successfully, one of the following error messages is displayed:

Open error! (n) Seek error! (n) Read error! (n) Write error! (n) Close error! (n)

Open process error on the FXoto volume. Seek process error on the FXoto volume. Read process error on the FXoto volume. Write process error on the FXoto volume. Close process error on the FXoto volume.

11.When you are finished allocating datasets on FXoto volumes, select Close to close the Allocation panel and exit the ALC utility.