6.When the FCU main panel opens, make sure that the Volume File field displays the FX volume definition file (datasetmount.dat). If the FX volume definition file is not displayed (or if incorrect), FCU will not be able to perform FX operations.

7.Make sure that the Parameter File field displays the desired FCU parameter definition file. If not, enter the desired FCU parameter definition file name (with complete path if not in the current directory), and select the File-Loadcommand to open the file. If you want to create a new file using the FCU GUI, see section Using the listvol Function (UNIX) for instructions.

8.The FCU main panel displays the first/next parameter set in the specified FCU parameter definition file. If you want to perform this FX operation, click OK. If not:

a)You can load the next parameter set using the File-Loadcommand.

b)You can delete the current parameter set from the FCU parameter definition file using the File-Deletecommand. The next parameter set loads automatically.

c)You can modify the current parameter set as follows: Change the FCU parameters as needed, and then use the File-Savecommand to save your changes in the FCU parameter definition file (replaces the previously loaded parameter set).

d)You can add a new parameter set to the end of the file as follows: Select File-Loaduntil you reach the end of the file, enter the desired parameters, and then select File-Saveto add the new line at the end. If you want to insert a new line between existing lines, edit the FCU parameter definition file later using a text editor.

9.When the desired FX operation is displayed, click OK to start the operation. (If the OK button is not enabled, you have not saved the current parameter set.)

10.If you started an FXmto operation and the target file already exists, FCU requests overwrite confirmation. Click OK to overwrite the target file, or click Cancel to cancel the operation.

11.When FCU starts the operation, the Status field displays the progress of the operation. If desired, while the operation is in progress, you can load another parameter set and click OK to start the next operation right after the current operation completes.

Note: Be careful when doing this. If you click buttons or menu commands while an operation is in progress, FCU will save and execute those commands when the current operation completes.

12.When the FX operation is complete, the Status field displays Complete. If an error occurred, the error information display opens automatically to display the error. See Appendix C for further information on error conditions.

Performing Cross-OS File Exchange Operations