Error

 

Error Message and Description

 

Recommended Action(s)

 

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

-141

 

Input file error: Invalid record format

 

Display the attribute information using the Help-MF-File

 

 

 

 

The RF type of the dataset is not

 

command. The RF type must be fixed-length or variable-

 

 

 

 

 

length.

 

 

 

 

supported.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-142

 

Input file error: Invalid block length

 

Display the attribute information using the Help-MF-File

 

 

 

 

The block length of the dataset is

 

command. The block length must be nonzero and cannot be

 

 

 

 

 

greater than 32 kB.

 

 

 

 

invalid.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-143

 

Input file error: Invalid record length

 

Display the attribute information using the Help-MF-File

 

 

 

 

The record length of the dataset

 

command. The record length must be nonzero and cannot

 

 

 

 

 

be greater than 32 kB.

 

 

 

 

is invalid.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-144*

Input file error: No data

 

Display the attribute information using the Help-MF-File

 

 

 

 

No data was found in the

 

command, and check the dataset size.

 

 

 

 

 

 

 

 

 

 

specified dataset.

 

 

 

 

 

 

 

 

 

 

 

-150*

 

Input file: Open error

 

Display the error code using the Help-Errorcommand. If a

 

 

 

 

A file open error occurred in the

 

FAL error code is displayed, refer to Table C.1. If a system

 

 

 

 

input dataset.

 

error code is displayed, please refer to the OS user manual.

 

 

 

 

 

 

 

 

-151*

Output file: Open error

 

Display the system error code using the Help-Error

 

 

 

 

A file open error occurred in the

 

command. Please refer to the OS user manual for

 

 

 

 

 

information on system errors.

 

 

 

 

output UNIX file.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-152

 

Output file: Get file data error

 

Collect information such as error log for troubleshooting.

 

 

 

 

A data acquisition error of the

 

 

 

 

 

 

output file occurred during an

 

 

 

 

 

 

FXotm operation.

 

 

 

 

 

 

 

 

 

 

 

-153

 

Processing data: Length check error

 

Make sure that the specified data length matches the actual

 

 

 

 

A data length to be processed by

 

data length. Collect information such as error log for

 

 

 

 

 

troubleshooting.

 

 

 

 

FXotm does not match.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-155

 

Buffer: Memory allocation error

 

Display the system error code using the Help-Error

 

 

 

 

Memory allocation failed.

 

command. Please refer to the OS user manual for

 

 

 

 

 

information on system errors.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-160*

Input file: Read error

 

Display the error code using the Help-Errorcommand. If a

 

 

 

 

A read error occurred in the input

 

FAL error code is displayed, refer to Table C.1. If a system

 

 

 

 

dataset.

 

error code is displayed, please refer to the OS user manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-161*

 

Output file: Write error

 

Display the system error code using the Help-Error

 

 

 

 

A write error occurred in the

 

command. Please refer to the OS user manual for

 

 

 

 

 

information on system errors.

 

 

 

 

output UNIX file.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-162

 

Output file: Code conversion error

 

Display the error code using the Help-Errorcommand. If a

 

 

 

 

An error occurred in the code

 

FAL error code is displayed, refer to Table C.1.

 

 

 

 

 

 

 

 

 

 

conversion to the output UNIX

 

 

 

 

 

 

file.

 

 

 

 

 

 

 

 

 

 

 

-163

 

Get processing data error

 

Display the error code using the Help-Errorcommand. If a

 

 

 

 

The acquisition of processing data

 

FAL error code is displayed, refer to Table C.1. If a system

 

 

 

 

failed.

 

error code is displayed, please refer to the OS user manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-165

 

Dataset error: Invalid data

 

Make sure that the z/OS dataset was generated correctly.

 

 

 

 

An invalid record length was

 

 

 

 

 

 

found in the dataset.

 

 

 

 

 

 

 

 

 

 

 

-170

 

Input file: Close error

 

Display the error code using the Help-Errorcommand. If a

 

 

 

 

A file close error occurred in the

 

FAL error code is displayed, refer to Table C.1. If a system

 

 

 

 

 

error code is displayed, please refer to the OS user manual.

 

 

 

 

input dataset.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-10

 

 