Hitachi MK-96RD647-01 241, Combination of otm data transfer, 242, 243, Combination of RDW=Yes

Models: MK-96RD647-01

1 226
Download 226 pages 34.71 Kb
Page 207
Image 207

-240

Parameter: Direction, PAD, and DEL not

 

matched

 

The combination of otm direction,

 

PAD=Yes, and DEL=No is not allowed.

 

 

-241

Parameter: Direction and RDW not matched

 

The combination of otm data transfer

 

direction and RDW=Yes is not allowed.

 

 

-242

Parameter: Code conv. and RDW not matched

 

The combination of RDW=Yes and code

 

conversion other than No is not allowed.

 

 

-243

Parameter: Padding and RDW not matched

 

The combination of RDW=Yes and

 

padding=Yes is not allowed.

 

 

-244

Parameter: Delimiter and RDW not matched

 

The combination of RDW=Yes and

 

delimiter=Yes is not allowed.

 

 

-245

Parameter : Specified VOLSER isn’t defined

 

Volume Definition file.

 

Specified VOLSER isn’t defined the volume

 

definition file.

 

 

-300

Parameter definition file : Length error

 

The record length in the parameter definition

 

file is too long.

 

 

-301

Mainframe file name : Length error

 

An input dataset name(in case of FXmto) or

 

an output dataset name(in case of FXotm)

 

in the parameter definition file is too long.

 

 

-302

Opensystem file name : Length error

 

An input filet name(in case of FXotm) or an

 

output file name(in case of FXmto) in the

 

parameter definition file is too long.

 

 

-303

Code conversion Length error

 

A code conversion file name in the

 

parameter definition file is too long.

 

 

-304

VSE: Length error

 

A VSE parameter in the parameter definition

 

file is not corrected.

 

 

-305

VSE record-format: Length error

 

The record format for VSE in the parameter

 

definition file is not corrected.

 

 

-306

VSE record-length: Length error

 

The record length for VSE in the parameter

 

definition file is not corrected.

 

 

For FXotm with the padding function, make sure that the delimiter option is specified as Yes (or set padding=No).

When the FX data transfer direction is otm, make sure that the RDW option is specified as No.

When the code conversion option is EA or File_name, make sure that the RDW option is specified as No. When RDW=Yes, the code conversion option must be specified as No.

When the padding option is specified as Yes, make sure that the RDW option is specified as No.

When the RDW option is specified as Yes, make sure that the padding option is specified as No.

When the delimiter option is specified as Yes, make sure that the RDW option is specified as No.

When the RDW option is specified as Yes, make sure that the delimiter option is specified as No.

Check whether specified VOLSER is defined in the volume definition file.

Specify the record length less than 3200 characters (do not include delimiter).

Specify an input/output dataset name less than 1025 characters.

Specify an input/output file name less than 1025 characters.

Specify a code conversion file name less than 1025 characters.

Specify a VSE parameter less than 21 characters.

Specify the record format for VSE less than 3 characters.

Specify the record length for VSE less than 6 characters.

Troubleshooting

7-19

Hitachi USP V Cross-OS File Exchange User’s Guide

Page 207
Image 207
Hitachi MK-96RD647-01 241, Combination of otm data transfer, 242, 243, Combination of RDW=Yes, Padding=Yes is not allowed