Table 9

CAP Magazine Slot Status Messages

 

 

 

 

Message

Explanation

 

 

 

 

EMPTY

This magazine slot does not contain a cartridge.

 

 

 

 

UNKNOWN

This magazine slot contains a cartridge, but the

 

 

library has not yet performed the necessary audit to

 

 

identify the cartridge.

 

 

 

 

UNREADABLE

This magazine slot contains a cartridge, but the

 

 

camera could not read the cartridge’s VOLSER label.

 

 

 

CAP States

When exporting or importing cartridges through the CAPs, the following CAP states may be displayed:

Table 10

CAP States

 

 

 

 

 

State

Explanation

 

 

 

 

CAP A (B) Open

Specified CAP is open for exporting or

 

 

importing of cartridges

 

 

 

 

CAP A (B) Closed

Specified CAP is closed and locked

 

 

 

 

CAP A (B) Transition

Specified CAP is stalled during an open or

 

 

close transition. This message indicates a

 

 

problem and an error is posted to the FSC log.

 

 

 

 

CAP A (B) Unknown

The specified CAP is in an unknown state.

 

 

Consult the FSC logs.

 

 

 

100 Operating in Automated Mode