Importing Cleaning Cartridges through the CAP

Note

This procedure assumes that you have enabled the Auto Clean

 

function by:

 

 

Loading cleaning cartridges into the reserved cells

Resetting the library once the cleaning cartridges are loaded

When you want to import cleaning cartridges through the CAP into the reserved cells:

1.Press the [CAP] button on the operator panel to open the CAP. The Open indicator will light.

Caution Possible halt to operation or damage to components. You must enter the cartridges properly, or else you might damage the robot or the drive or cause the library to stop operating. Use only cartridges designed for your type of drives.

2.Load cartridges into the magazine. You can do this one of two ways:

a.Pull out and down on the magazine handle.

b.Remove the magazine by lifting it out (see Figure 28 on page 108).

Note

You can use the snap-on retention cartridge cover to keep

 

cartridges in place when carrying the magazine. Remove the

 

clear cover from the back of the magazine by lifting the side

 

edge. To protect the cartridges, place the slots on one edge of

 

the cover into the grooves on the side of the magazine’s top

 

panel and snap the other edge into place.

 

 

3.Enter the cartridges into the magazine so that they lie flat, with the VOLSER label facing toward you, the customer label facing down, and the reel facing away from you. (See Figure 29 on page 109 and Figure 30 on page 110.)

4 Chapter

Chapter 4

Operating in Automated Mode 105