Enabling/Disabling Fast Load
These two terms are defined as follows:
Fast load on: | The robot will mount a tape to a drive and then | |
|
| immediately report the move completed. |
Fast load off: | The robot will mount a tape to a drive and wait at the | |
|
| drive location until the tape is completely loaded before |
|
| reporting the move completed. |
|
| |
Note | Some host software does not support the fast load enabled | |
| option. |
|
|
|
|
Enable or disable the Fast Load feature from the Lib Config Menu. To set either feature:
1.At the Lib Config Menu screen, press the arrow button until the cursor underscores FAST LOAD.
2.Press the [SELECT] button. An editing screen appears.
3.Press the up and down arrow buttons to select either ON or OFF.
4.Press the [SELECT] button to save the changes. (You may press the [MENU] button to abort.)
5.If you have already changed the library’s SCSI ID and are planning to exit the main Configuration Menu at this time, you must press the [RESET] button. If you want to set other configuration values, continue with the next section.
If you have not changed the library’s SCSI ID and are not setting other configuration values, press the [MENU] button until you exit all menus.