Caution Possible damage to the hand assembly. Remove the magazine’s retention cover before loading the magazine into the CAP.
4.Return the magazine to its closed position.
5.Press the [CAP] button on the operator panel to close the CAP.
6.Press the [MENU] button to return the display to the Main Menu.
7.Press the arrow buttons until the cursor underscores CLEANING INFO.
8.Press the [SELECT] button.
The panel displays the Cleaning Info menu (see Figure 12 on page 47).
9.Press the arrow buttons until the cursor underscores IMPORT CARTRIDGE.
10.Press the [SELECT] button.
The Import Clean Cartridges screen appears, which lists all reserved cell cleaning cartridges by domain (or drive type), and VOLSER.
11.Select the cleaning cartridges you want to import by:
a.Moving the cursor to the desired cartridge entry on the list
b.Pressing the [SELECT] button. A selected cleaning cartridge is then highlighted (in reverse video)
c.Repeating Steps a and b until you have selected all the cartridges you want to import
Note | There is no “undo” available on this menu. If you select a |
| cartridge by mistake, you must exit the menu by pressing the |
| [MENU] button. Then you must start again at Step 10. |
|
|
12. Press the [SELECT] button to import the cartridges.