Library Power Switch

Note

Be aware that each PDU supplies power to the robotics and half

 

of the drives. When the library has two PDUs (and a drive

 

column with two power cords), each PDU is connected to

 

separate branch AC circuit.

 

If you are installing multiple drives in the library (and the library

 

is a newer model with two power cords to the drive column), HP

 

recommends that you configure some drives in the upper five

 

slots, and some drives in the lower five slots in the drive column.

 

With this configuration, if one PDU loses power, some drives and

 

the library robotics will remain operational.

 

 

The library power switch is a circuit breaker or breakers behind the right front door of the library. Figure 23 on page 62 shows the power switch location. This switch, attached to the AC power distribution unit (PDU), controls the AC power to the library and drive column.

The power switch has two configurations:

A single breaker on the AC power distribution unit controls the library and a single drive column.

A second breaker, located on the second power distribution unit, powers the second drive column and an optional second library power supply.

Note

Your library has two circuit breakers:

 

The second PDU must be connected to a separate electrical

 

circuit.

 

If only one breaker is powered off, the second breaker will still

 

be powered on.

 

 

60 Library Power Switch

Chapter 2