Setting the Interfaces

Setting DSn Transmit Interface

Description DSn transmit interface settings should match network equipment settings of Rate, Termination and Line Code and determine the Payload to be tested.

TIP:

To set the Transmitter and Receiver to the same interface settings

 

choose OTHER

SETTINGS CONTROL

COUPLED .

 

 

 

 

HOW TO:

1 Choose the required SIGNAL rate.

 

Rates of DS1, DS3, 2 Mb/s and 34 Mb/s are available.

 

2 If you have chosen 2 Mb/s as the SIGNAL rate, choose the required

 

CLOCK SYNC source - internally generated or recovered from the

 

received DSn signal.

 

If Jitter, Option 204, 205 or 206, is fitted and SIGNAL 2 Mb/s is chosen

 

a 2M REF choice is added to the menu. This allows you to choose the

 

synchronization source for the 2 Mb/s reference. The synchronization

 

source is supplied from the SONET Clock module. It can be internally

 

generated, derived from an external clock or recovered from the

 

SONET received signal.

2