Making Measurements
Making DSn Analysis Measurements
Making DSn Analysis Measurements
Description G.821, G.826, M.2100, M.2110 and M.2120 analysis results are provided
for all relevant DSn and DSn Payload error sources.
In addition the following results are provided:
Cumulative error count and error ratio
Short Term error count and error ratio
Alarm Seconds
SIG/BIT Monitor. See "Monitoring Signaling Bits " page 76.
HOW TO: | 1 If SONET is chosen as the interface, set up the Receive Interface and |
| Payload required. See "Setting SONET Receive Interface " page 17. If |
| required set up the Transmit Interface and Payload. See "Setting |
| SONET Transmit Interface " page 4. |
2If DSn is chosen as the interface, set up the DSn receive interface. See "Setting DSn Receive Interface " page 15. If required set up the DSn
transmit interface. See "Setting DSn Transmit Interface " page 2.
3Press RUN/STOP to start the measurement.
4If SONET is chosen as the interface, you can view the analysis results on the RESULTS DSn PAYLOAD ERROR ANALYSIS display
If DSn is chosen as the interface, you can view the analysis results on | |
the RESULTS DSn | ERROR ANALYSIS display. |
71