Selecting Test Features

 

Adding Pointer Adjustments

 

 

 

 

Pointer Sequence

 

Description

 

 

 

 

 

GR-253 5-32(c)

 

This selection is only available if you have selected VT1.5 mapping.

 

PERIODIC ADD (26-1

 

The sequence pattern is 26 pointer movements followed by 1

 

Pattern)

 

missing pointer movement. The added adjustment occurs 2 ms after

 

 

 

the 13th pointer adjustment. Pointer polarity is selectable and the

 

 

 

time interval between pointer adjustments programmable to 200

 

 

 

ms, 500 ms, 1 s, 2 s, 5 s or 10 s. Added adjustments occur every 30

 

 

 

seconds or every repeat of the 26-1 pattern, whichever is longer.

 

 

 

 

 

T1.105 A5 PERIODIC

 

An 87-3 pattern is selected. The sequence pattern is 87 pointer

 

CANCEL (87-3 pattern)

 

movements followed by 3 missing pointer movements with a

 

GR-253 5-33(d)

 

cancelled pointer movement at the 87th pointer. Pointer polarity is

 

 

 

selectable, and the time interval between pointer adjustments can

 

 

 

be set (see Note 1). Cancelled adjustments occur every 30 seconds or

 

 

 

every repeat of the 87-3 pattern, whichever is longer.

 

 

 

 

 

T1.105 A5 PERIODIC

 

Periodic Single adjustments, with selectable polarity and cancelled

 

CANCEL (Continuous

 

adjustment (1 less). The time interval between pointer adjustments

 

Pattern)

 

can be set (see Note 1). Cancelled adjustments occur every 30

 

GR-253 5-34(d)

 

seconds or every repeat of the 87-3 pattern, whichever is longer.

 

 

 

 

 

GR-253 5-32(d)

 

This selection is only available if you have selected VT1.5 mapping.

 

PERIODIC CANCEL (26-1

The sequence pattern is 26 pointer movements followed by 1

 

pattern)

 

missing pointer movement. The cancelled adjustment is the 26th

 

 

 

pointer adjustment, that is the one before the regular gap of 1.

 

 

 

Pointer polarity is selectable and the time interval between pointer

 

 

 

adjustments programmable to 200 ms, 500 ms, 1 s, 2 s, 5 s or 10s.

 

 

 

Cancelled adjustments occur every 30 seconds or every repeat of the

 

 

 

26-1 pattern, whichever is longer.

 

 

 

 

 

 

For SPE pointers the sequence interval is selectable from 7.5 ms, 10, 20,

NOTE

 

30, 34 ms; 40 to 100 ms in 10 ms steps, 100 to 1000 ms in 100 ms steps

 

1, 2, 5, 10 seconds.

 

For VT pointers the sequence interval is selectable from: 200 ms, 500 ms,

 

1, 2, 5 and 10 seconds.

 

For SPE pointers the minimum spacing between adjustments is 500 us.

 

For VT pointers the minimum spacing between adjustments is 2 ms.

 

 

 

 

59

Page 69
Image 69
HP BER 718 37718A manual GR-253 5-34d