| Selecting Test Features | ||
| Adding Pointer Adjustments | ||
|
|
|
|
Pointer Sequence |
| Description |
|
|
|
|
|
|
| This selection is only available if you have selected VT1.5 mapping. |
|
PERIODIC ADD |
| The sequence pattern is 26 pointer movements followed by 1 |
|
Pattern) |
| missing pointer movement. The added adjustment occurs 2 ms after |
|
|
| the 13th pointer adjustment. Pointer polarity is selectable and the |
|
|
| time interval between pointer adjustments programmable to 200 |
|
|
| ms, 500 ms, 1 s, 2 s, 5 s or 10 s. Added adjustments occur every 30 |
|
|
| seconds or every repeat of the |
|
|
|
|
|
T1.105 A5 PERIODIC |
| An |
|
CANCEL |
| movements followed by 3 missing pointer movements with a |
|
|
| cancelled pointer movement at the 87th pointer. Pointer polarity is |
|
|
| selectable, and the time interval between pointer adjustments can |
|
|
| be set (see Note 1). Cancelled adjustments occur every 30 seconds or |
|
|
| every repeat of the |
|
|
|
|
|
T1.105 A5 PERIODIC |
| Periodic Single adjustments, with selectable polarity and cancelled |
|
CANCEL (Continuous |
| adjustment (1 less). The time interval between pointer adjustments |
|
Pattern) |
| can be set (see Note 1). Cancelled adjustments occur every 30 |
|
|
| seconds or every repeat of the |
|
|
|
|
|
|
| This selection is only available if you have selected VT1.5 mapping. |
|
PERIODIC CANCEL | The sequence pattern is 26 pointer movements followed by 1 |
| |
pattern) |
| missing pointer movement. The cancelled adjustment is the 26th |
|
|
| pointer adjustment, that is the one before the regular gap of 1. |
|
|
| Pointer polarity is selectable and the time interval between pointer |
|
|
| adjustments programmable to 200 ms, 500 ms, 1 s, 2 s, 5 s or 10s. |
|
|
| Cancelled adjustments occur every 30 seconds or every repeat of the |
|
|
|
| |
|
|
|
|
| For SPE pointers the sequence interval is selectable from 7.5 ms, 10, 20, | ||
NOTE | |||
| 30, 34 ms; 40 to 100 ms in 10 ms steps, 100 to 1000 ms in 100 ms steps | ||
| 1, 2, 5, 10 seconds. | ||
| For VT pointers the sequence interval is selectable from: 200 ms, 500 ms, | ||
| 1, 2, 5 and 10 seconds. | ||
| For SPE pointers the minimum spacing between adjustments is 500 us. | ||
| For VT pointers the minimum spacing between adjustments is 2 ms. | ||
|
|
|
|
59