Selecting Test Features

Adding Frequency Offset to the DSn Signal

Adding Frequency Offset to the DSn Signal

Description You can add frequency offset to the interface DSn SIGNAL at all rates. Frequency Offset can be added at preset ITU values or as User defined values in the range ±100 ppm. The preset values change with the SIGNAL rate chosen as shown:

 

 

 

 

DS-1

(1.544 Mb/s)

+ 32 ppm

−32 ppm

2 Mb/s (E1)

+ 50 ppm

−50 ppm

 

 

 

34 Mb/s (E3)

+ 20 ppm

−20 ppm

 

 

 

 

DS-3

(44.736 Mb/s)

+ 20 ppm

−20 ppm

HOW TO:

1 Choose the FREQUENCY OFFSET required.

2If you choose USER OFFSET, you can set the frequency offset to be between -100 ppm and +100 ppm in 1 ppm steps.

Select the field immediately below USER OFFSET and use

DECREASE DIGIT

, INCREASE DIGIT ,

 

and

 

to set the

 

 

 

 

 

 

 

frequency offset. (The amount of frequency offset can be varied while measurements are taking place.)

33

Page 43
Image 43
HP BER 718 37718A manual Adding Frequency Offset to the DSn Signal