Setting the Interfaces

Setting SONET Transmit Interface

Setting SONET Transmit Interface

Description SONET transmit interface settings should match the network equipment settings of Rate, Wavelength and Mapping, determine the payload to be tested and set background conditions to prevent alarms while testing.

TIP:If you wish to set the HP 37718A transmitter and receiver to the same interface settings choose OTHER SETTINGS CONTROL COUPLED .

HOW TO:

1

Make your choice of SIGNAL rate.

 

 

If Option 106, Dual Wavelength optical module, is fitted and an optical

 

 

rate is chosen, choose the required wavelength (1550) or (1310).

 

 

If STS-1 is chosen, choose the required interface level.

 

 

Choose INTERNAL unless THRU MODE is required. If THRU MODE is

 

 

chosen, see "Setting SONET THRU Mode " page 11.

 

2

Make your choice of CLOCK synchronization source. The RECEIVE

 

 

clock synchronization choice depends on the SONET Receive Interface

 

 

choice.

 

 

EXTERNAL allows a choice of MTS, BITS or 10 MHz clocks.

 

3

If required choose the FREQUENCY OFFSET value. See “Adding

 

 

Frequency Offset to SONET Signal” page 31.

4

Page 14
Image 14
HP BER 718 37718A manual Setting Sonet Transmit Interface