NOTE

Using Instant Capacity to Manage Processing Capacity

Replacement of Failed Processors

Replacement of Failed Processors

LPMC and HPMC

If an active processor fails with a Low Priority Machine Check (LPMC), in a partition with Instant Capacity, its processor capacity is replaced instantly by an inactive processor, if any are available in the partition. The failed processor is marked for deconfiguration during the next system reboot.

See “LPMC Deactivations in Virtual Partitions” on page 140 for additional considerations in a virtual partition environment.

If an active processor fails with a High Priority Machine Check (HPMC), then upon reboot, the failed processor is deconfigured and its processor capacity is instantly replaced by an inactive processor, if any are available in the partition.

In both of the above scenarios, you should replace the failed processor in a timely manner using your normal hardware support process.

Failed Monarch Processors

Monarch processors (see page 157 for a definition) that are failing with a LPMC are not instantly replaced. When a monarch processor experiences a LPMC, the LPMC monitor marks the processor for deconfiguration; however, the LPMC monitor cannot deactivate the processor, unless the system is rebooted. Deactivation of a monarch processor is not possible because it is the controlling processor of the operating system (CPU 0). Therefore, Instant Capacity cannot replace a (failing) monarch processor.

If your system has only one active processor, it is considered a monarch processor, and it cannot be replaced online. A reboot of the system is required to replace the failing monarch processor.

Chapter 4

71