HP UX IPFilter Software Source statement Instruction, Information in dcache Measurement Reports

Models: UX IPFilter Software

1 277
Download 277 pages 61.39 Kb
Page 197
Image 197

Source statement

Instruction

Table 21 Information in dcache Measurement Reports

Column

Description

% Total Dcache

Total cache miss latency cycles, expressed as a percent of the total cycles.

Latency Cycles

For example, in Example 5, 84.29 percent of the total cycles were expended on data cache

 

 

misses.

Sampled Dcache

Total number of sampled L1 (or FLD) data cache accesses attributed to the given program object.

Hits

Enabled only on Intel® Itanium® 9500 series processors.

Sampled Dcache

The percentage of cycles spent on the data cache misses as compared to the total dcache cycles(hits

Miss Rate

and misses combined).

Sampled Dcache

Total number of sampled data cache misses attributed to the given program object.

Misses

 

Dcache Latency

Number of cycles expended on data cache misses summed across samples for the given program

Cycles

object.

Avg. Dcache

Average number of cycles expended on data cache misses across samples for the given program

Laten. Cycles

object.

Latency Buckets as

The latency data is reported under eight different buckets: three for cache information and five for

% Misses

memory information.

 

The top row(s) of the heading specifies the names of the cache level (such as L2 or L3) and system

 

memory names. For example, in Example 5, cache levels L2 and L3 are shown and the system

 

memory is shown as simply Memory (spanning five buckets).

The system memory buckets vary depending on whether your system is a low-end server, direct-connected cell system, or Superdome server. Possible memory bucket headings are:

Memory: System memory access

loc c2c: Local cache-to-cache (C2C) transactions between CPUs in the same front side bus (FSB) (Superdome Integrity server only)

loc memory: Cell local memory access (Superdome Integrity server only)

1 hop: Remote memory access that is one hop across the crossbar (Superdome Integrity server only)

2 hop: Remote memory access that is two hops across the crossbar (Superdome Integrity server only)

1&2 c2c: One- or two-hop cache-to-cache (C2C) remote memory access (Superdome Integrity server only)

The last row of the headings specifies the latency value in cycles. For example, in Example 5, the L2 data cache has a latency of 7 cycles. All data cache misses with latency of less than or equal to 7 cycles are grouped under the L2 bucket.

The buckets in Example 5 under L3 have latencies of 14 and 64 cycles. The bucket under 14 captures all latencies greater than 7 cycles and less than or equal to 14 cycles. The bucket under 64 captures latencies that are greater than 14 cycles and less than or equal to 64 cycles.

On an rx4640 Integrity server, as shown in Example 5, the last five buckets capture misses that are serviced from system memory. The first bucket under the Memory heading captures latencies that are greater than 64 cycles and less than or equal to 150 cycles. The last bucket captures all latencies greater than 450 cycles.

The reported values are the percentage of sampled dcache misses in the specified latency range. For example, in Example 5, in the Function Totals column, the value of 92 in the L2 data cache means that 92 percent of all data misses in the function goo are satisfied by the L2 cache. Similarly, the value in the first bucket under the Memory heading means that 5 percent of the misses were having latencies in the range greater than 64 and less than or equal to 150 cycles.

If you turn off the latency bucket information by using the --latency-buckets False option, the information in the Latency Buckets as % Misses column is not displayed.

dcache Measurement Report Description 197

Page 197
Image 197