Temperature, humidity, and altitude

The following table provides temperature, humidity, and altitude specifications for the 4560SLX Tape Library.

Table 15. Temperature, humidity, and altitude specifications (non-operating - long term)

Non-operating - long term (unpacked or packed)

Dry Bulb Temperature

-40°C to 60°C

 

 

Temp Gradient

20°C/hr. (across the range)

 

 

Temperature Shock

15°C (over 2 min.)

 

 

Wet Bulb Temperature

30°C

 

 

Relative Humidity

5% to 95% (non-condensing)

 

 

Humidity Gradient

10%/hr

 

 

Altitude (sea level)

-1000 ft. to +10,000 ft.

 

 

Table 16. Temperature, humidity, and altitude specifications (transit - short term)

Transit - short term (packed 7 days)

Dry Bulb Temperature

-40°C to 60°C

 

 

Temp Gradient

25°C/hr. (across the range)

 

 

Temperature Shock

15°C (over 2 min.)

 

 

Wet Bulb Temperature

30°C

 

 

Relative Humidity

5% to 95% (non-condensing)

 

 

Altitude (sea level)

-1000 ft. to +10,000 ft.

 

 

Shock

The following tables provide operating, non-operating, transit/storage, and physical drop test shock specifications for the 4560SLX Tape Library.

Table 17. Shock specifications (operating)

Operating (within spec - no damage)

Peak Acceleration

1.5 G’s

 

 

Duration

11 ms

 

 

Waveshape

1/2 sine pulses

 

 

Application

X,Y,Z axes, repeat 3 times

 

 

Table 18. Shock specifications (non-operating)

Non-operating (unpacked - no damage)

Peak Acceleration

25 G’s

 

 

Duration

11 ms

 

 

Waveshape

1/2 sine pulses

 

 

Application

X,Y,Z axes, repeat 3 times

 

 

Appendix C. Specifications 93

Page 103