7.Connect the male to male
8.Connect the other
The
9.Connect the power cord to the router.
10.Supply power to the router. Power up the router before the modules.
11.Turn on the library modules as shown in Figure 86.
1 | Power cord |
2 | Power switch |
3 | Touch screen |
Figure 86. Powering up the library
a.Connect the power cord to the power supply’s receptacle.
b.Toggle the power switch located on the power supply to ON.
c.Repeat steps a and b for all modules connected to the cartridge elevator.
d.Press the slave module touch screens to apply power to the libraries.
e.Press the master touch screen to apply power to all of the libraries.
Verifying firmware level of the slave modules
To ensure reliable
Verify the firmware level of the slave modules as follows:
1.After the POST completes, press Menu on the first slave module.
2.Press Library Info in the View System Data area.
3.The firmware revision is deployed on the Miscellaneous Library Info screen.
4.Repeat step 1 through step 3 for the other slave modules.
After the flash operation completes, the slave modules will reboot.
Appendix B. Adding a library module 87