To move a selected cartridge using Web TCL, complete the following procedure:

1.Specify the source slot and destination.

2.Click the Execute the move button.

A screen is displayed notifying the user that selecting confirm will cause the library to go offline during the move media operation.

3.Click Confirm to proceed with the move.

Setup

Click Setup to set various configuration options. Select one of the configuration options from the menu to view or change parameters. The settings correspond to those in the Configure Menu on the library touch screen.

Functions

Click Functions to execute a cleaning or a diagnostic.

The functions available from this screen include the following:

vPerform a drive cleaning operations

vPerform a free running library diagnostics

vPerform standard library diagnostics

vDrive flash operations

vReset Web TLC

vReset library

History

Click History to view a list of files that can be displayed or downloaded. When you select a file, a Save As window is displayed, which enables you to select a network destination for the download. When you click Display Trace, the trace log will be viewed through the browser.

664560SLX Tape Library: User’s Guide

Page 76
Image 76
IBM 4560SLX warranty Functions, History