Table 19. Shock specifications (transit/storage)
Transit/storage (packed - no damage)
Peak Acceleration | 30 G’s |
|
|
Duration | 30 ms |
|
|
Waveshape | 1/2 sine pulses |
|
|
Application | X,Y,Z axes, repeat 3 times |
|
|
Table 20. Shock specifications (physical drop test)
Physical drop test (packaged - no damage)
Drop Test Distance | 12 in. (30.5 cm) |
|
|
Application | Per ISTA (1 time) |
|
|
Vibration
The following tables provide operating,
Table 21. Vibration specifications (operating)
Operating (within spec - no damage)
Frequency Range | |
|
|
Peak Acceleration | .25 G’s |
|
|
Waveshape | Sinusoidal, 1 octave/min |
|
|
Application | X,Y, Z axes, 2 sweeps pers |
|
|
Table 22. Vibration specifications
Non-operating (unpacked - no damage)
Frequency Range | |
|
|
Peak Acceleration | 1.0 G’s |
|
|
Waveshape | Sinusoidal, 1 octave/min |
|
|
Application | X,Y, Z axes, 2 sweeps pers |
|
|
Table 23. Vibration specifications (transit/storage) | |
|
|
Transit/storage (packed - no damage) |
|
|
|
Frequency Range | |
|
|
Peak Acceleration | 2.0 G’s |
|
|
Waveshape | Sinusoidal, 1 octave/min |
|
|
Application | X,Y, Z axes, 2 sweeps pers |
|
|
Primary power
This section provides information on voltage and frequency limits, power requirements, sag/surge protection, and power line disturbance for the 4560SLX Tape Library.
944560SLX Tape Library: User’s Guide