7.13Testing Pen Calibration

If your terminal is not correctly interpreting pen touches, use this test to adjust the pen calibration. This test is for the i6550 only.

 

Display

 

 

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To access the extended menu, restart the terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

by pressing [1] + [CAN] + [OK]; while the terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is starting up, access the extended menu by

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pressing the [1] and [3] keys simultaneously.

 

 

 

 

 

 

Extended Menu

 

 

Press [

], [Enter] to select Diagnostic Menu.

 

 

Serialnum Inject

 

 

 

 

 

 

 

 

 

 

System Config

 

 

 

 

 

 

System Info

 

 

 

 

 

 

Supervisor Menu

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diagnostic Menu

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diagnostic Menu

 

 

Press [

], [Enter] to select Pen Calibration.

 

 

Display

 

 

 

 

 

 

 

 

 

 

Keypad

 

 

 

 

 

 

Beeper

 

 

 

 

 

 

RS232

 

 

 

 

 

 

Tailgate

 

 

 

 

 

 

USB

 

 

 

 

 

 

Mag Stripe Reader

 

 

 

 

 

 

Smart Card Reader

 

 

 

 

 

 

SAM

 

 

 

 

 

 

Touch Screen

 

 

 

 

 

 

Signature Capture

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pen Calibration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Please remove hands/objects

 

 

 

 

 

 

 

from around the display

 

 

 

 

 

 

Calibration will start in 3

 

 

 

 

 

 

seconds…

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Using the stylus, tap the four-box grid. The box

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calibrate Pen

 

 

 

 

moves around to the next corner; tap again.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Please tap box

 

 

Repeat until you are notified if the test was

 

 

 

 

 

 

 

 

 

successful.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ingenico 6500 User’s Guide

83

Page 91
Image 91
Ingenico 6500 manual Testing Pen Calibration