ID

Parameter Name

Description

 

Value

 

Data

53

PAR_COM2_PARITY

COM2 parity setting

1 – COM_PARITY_NONE*

 

Uint8

 

 

 

 

2 – COM_PARITY_ODD

 

 

 

 

 

 

3 – COM_PARITY_EVEN

 

 

 

 

 

 

 

 

 

54

PAR_COM2_LAN_ADDRES

COM2 LAN address

 

1 byte number, default = 0x65

 

Uint8

 

S

setting

 

 

 

 

 

 

 

 

 

 

 

55

PAR_COM2_RETRY_COUN

COM2 failure retry count

 

1~10, default 3 times

 

Uint8

 

T

 

 

 

 

 

 

 

 

 

 

 

 

56

PAR_COM2_RESP_TIMEO

COM2 response timeout

 

4 bytes number, >0, 10ms a unit,

 

Uint3

 

UT

 

 

default=1000

 

2

 

 

 

 

 

 

 

57

PAR_COM2_POLL_TIMEO

COM2 poll timeout

 

4 bytes number, >0, 10ms a unit,

 

Uint3

 

UT

 

 

default=3000

 

2

 

 

 

 

 

 

 

58

PAR_COM2_TURNAROUN

COM2 turn around

 

4 bytes number, >0, 10ms a unit. ,

 

Uint3

 

D_TIMEOUT

timeout

 

default=300

 

2

 

 

 

 

 

 

 

59

PAR_COM2_INTERFACE_T

COM2 connection

 

PORT_RS232 *

 

uint8

 

YPE

interface type

 

1 – RS232

 

 

 

 

 

 

 

 

 

 

 

 

PORT_RS485

 

 

 

 

 

 

2 – RS485

 

 

 

 

 

 

PORT_TAILGATE

 

 

 

 

 

 

3 – Tailgate

 

 

 

 

 

 

PORT_USB

 

 

 

 

 

 

4 – USB

 

 

 

 

 

 

PORT_ETHERNET

 

 

 

 

 

 

5 – Ethernet

 

 

 

 

 

 

PORT_ATMODEM

 

 

 

 

 

 

6 – Dial

 

 

 

 

 

 

PORT_3201

 

 

 

 

 

 

7 – 3201

 

 

 

 

 

 

 

 

 

60

RESERVED

COM2 setting reserved.

 

N/A

 

 

~6

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

Ingenico 6500 User’s Guide

69

Page 77
Image 77
Ingenico 6500 manual PARCOM2PARITY