Processor—Thermal Management

5.1Thermal Metrology

The maximum Thermal Test Vehicle (TTV) case temperatures (TCASE-MAX) can be derived from the data in the appropriate TTV thermal profile earlier in this chapter.

The TTV TCASE is measured at the geometric top center of the TTV integrated heat spreader (IHS). The following figure illustrates the location where TCASE temperature

measurements should be made.

Figure 15. Thermal Test Vehicle (TTV) Case Temperature (TCASE) Measurement Location

Measure TCASE at

the geometric center of the package

37.5

37.5

Note: THERM-X OF CALIFORNIA can machine the groove and attach a thermocouple to the IHS. The supplier is subject to change without notice. THERM-X OF CALIFORNIA, 1837 Whipple Road, Hayward, Ca 94544. Ernesto B Valencia +1-510-441-7566 Ext. 242 ernestov@therm-x.com. The vendor part number is XTMS1565.

5.2Fan Speed Control Scheme with Digital Thermal Sensor (DTS) 1.1

To correctly use DTS 1.1, the designer must first select a worst case scenario TAMBIENT, and ensure that the Fan Speed Control (FSC) can provide a ΨCA that is equivalent or

greater than the ΨCA specification.

The DTS 1.1 implementation consists of two points: a ΨCA at TCONTROL and a ΨCA at DTS = -1.

Intel® Xeon® Processor E3-1200 v3 Product Family

 

Datasheet – Volume 1 of 2

June 2013

64