5.1Thermal Metrology
The maximum Thermal Test Vehicle (TTV) case temperatures
The TTV TCASE is measured at the geometric top center of the TTV integrated heat spreader (IHS). The following figure illustrates the location where TCASE temperature
measurements should be made.
Figure 15. Thermal Test Vehicle (TTV) Case Temperature (TCASE) Measurement Location
Measure TCASE at
the geometric center of the package
37.5
37.5
Note:
5.2Fan Speed Control Scheme with Digital Thermal Sensor (DTS) 1.1
To correctly use DTS 1.1, the designer must first select a worst case scenario TAMBIENT, and ensure that the Fan Speed Control (FSC) can provide a ΨCA that is equivalent or
greater than the ΨCA specification.
The DTS 1.1 implementation consists of two points: a ΨCA at TCONTROL and a ΨCA at DTS =
Intel® Xeon® Processor |
|
Datasheet – Volume 1 of 2 | June 2013 |
64 | Order No.: |