[Local Printer Parallel Port]: IEEE Timing Log (for ECP and Nibble Modes)

18.3. IEEE Timing Log (for ECP and Nibble Modes)

This parameter was introduced with release level 2111.

Very small timing variations can cause failure to print when using bi-directional communication, which is to say Nibble Mode or ECP mode.

By letting the timing log stay switched on, you will be able to see in the System Log if the failure to print seems to be caused by this kind of a timing problem. The System Log will also include a suggested solution.

Sometimes the suggestion will be to try the job again with the timing log switched off. If the print still doesn’t come through, you probably have to change the negotiation mode to Compat- ible.

Value

Yes*

No

Comments

Switched on. This is the default setting. It has no effect if the local printer parallel port is set to Compatible Mode.

This value is provided as a formality. Being that Yes does not cause any performance problems, choosing No is purely a matter of personal taste in cases where you know that the setup functions perfectly with bi-directional negotiation.