Services in “Input Control”: ThinPrint

 

to use an extensions describing a printer ID, for example:

 

192.168.51.100:2#HP3Si

 

The ThinPrint server sends the value between the colon and

 

the # mark to the Intermate1xx. Provided that this is one of the

 

values listed on the table below, it will override the settings

 

“Output to” on the [ThinPrint] configuration page in the

 

Intermate1xx.

 

 

Value

Where the output is sent by the print server

 

 

1

Local parallel printer port (the printer on which the Intermate1xx is attached). This printer

 

skips the logical layer, so there are no possibilities for pre- or post-processing, string

 

substitution, or functioning in a printer pool with load balancing.

 

 

1x Two-digit values starting with the digit 1 allow the user to choose a network printer without having to go through the logical printer layer. These values only work on G32. Used on G22, they will cause the print job to be directed to the local printer. A message will be written to the SystemLog.

11

Network Destination 1

 

 

12

Network Destination 2

 

 

13

Network Destination 3

 

 

14

Network Destination 4

 

 

2x Two-digit values starting with the digit 2 allow the user to choose a logical printer (1-8, inclusive).

 

 

21

Logical Printer 1

 

 

22

Logical Printer 2

 

 

23

Logical Printer 3

 

 

24

Logical Printer 4

 

 

25

Logical Printer 5

 

 

26

Logical Printer 6

 

 

27

Logical Printer 7

 

 

28

Logical Printer 8

 

 

all other

The setting on the [ThinPrint] configuration page will be used.

values

Note that the only way to direct a job to Logical Printer 0, and thus to the System Target

 

Printer configured in Basic > [General], is to set “Output to” on the [ThinPrint] configuration

 

page to “Logical Printer 0" and avoid overruling that setting.

 

 