Overview of Types of Resets: Restore Factory Defaults: TEST Button

aIntermate101Turn the unit off by pulling the power supply jack out of the Intermate101print server.

bKeep your eyes on the LEDs.

cPut the jack back in.

dBoth LEDs will light up.

eAfter a few seconds the Line LED (green) will go off, while the Error LED (red) is still on. This is the signal to press the TEST Button in.

fHow long you hold it depends on what kind of reset you want to do. You measure the length of holding by following the LED lighting sequence, so you don’t need a watch or clock.

Desired Result

LED lighting sequence

 

 

Reset IP address to 0.0.0.0,

The Error LED (red) starts blinking. Let go after 1 or 2 blinks.

subnet mask to 255.255.255.0

The confirmation page gets printed and the Error LED

and default gateway to 0.0.0.0

goes off.

 

 

 

Restore All Defaults.

The Error LED (red) starts blinking. Keep holding.

This is just like the remote

The Error LED (red) goes off, so now both lights are off.

“Restore All Defaults”.

Both LEDs turn on. Let go of the Button.

 

 

The confirmation page gets printed and the Line LED (green)

 

lights up.

 

 

gReboot. A hardware reboot is easiest— use the power supply jack to power the print server Off and then On.

Intermate100 and Intermate101 Print Server Administration Manual

224

Page 224
Image 224
Intermate 100 manual Desired Result LED lighting sequence