Presetting the Time Code from the LCD Screen

The time code can be preset directly from the LCD screen without opening the TC/UB/CLOCK menu screen.

CAUTION

PRESET mode is not available in the following.

TCG SOURCE item in the TC/UB/CLOCK menu screen is set to EXTERNAL.

TC GENE. switch is set to REGEN.

TC DUPLI. item in the TC/UB/CLOCK menu screen is set to ON.

Menu screen is displayed.

RECORDING mode is active.

Switching to CAM/VTR mode (When VTR indicator is blinking).

Blink

2.Press the USER2 button to reset all data.

Data becomes “00:00:00:00” and the hour digit starts blinking.

3.Set the time code (hour, minute, second and frame). The blinking digit can be set.

1Turn the SHUTTER dial to change the value of the blinking digit. Turn the SHUTTER dial up to increase the value and down to decrease the value.

Setting

„TC/UB/CLOCK menu screen

Set TCG SOURCE to INTERNAL.

Set framing of the time code generator in DROP FRAME. (When set to FRAME RATE 60/30)

Set to enable/disable user’s bit recording in UB REC. (When set to FRAME RATE 50/25)

„Set the TC GENE switch to REC or FREE.

MEMO

See page 44 for details on the above settings.

„Set the TC DISPLAY switch.

Set to TC to preset time code and UB to preset user’s bit.

2Press the SHUTTER dial to change the blinking digit.

3Repeat steps 1 and 2 and continue setting for each row.

4.Press the USER3 button to confirm the setting data.

• The LCD screen returns to the original screen.

Presetting User’s Bit

You can specify the user’s bit with a number or character between 0 - F.

CAUTION

All digits of user’s bit cannot be set to F.

If all digits are set to F and read, user’s bit is deemed as undefined during playback.

Operation

This section describes presetting of the time code.

 

 

USER 2 button

 

 

USER 1 button

USER 3 button

 

 

USER 1

USER 2 USER 3

 

 

 

SHUTTER

 

 

ND FILTER

SHUTTER dial

 

 

2

 

 

 

 

VF BRIGHT

1

 

 

 

 

USER 1

USER 2 USER 3

OFF

MENU

 

 

 

ND FILTER

 

 

 

2

 

 

STATUS button

1

 

 

 

MENU

 

 

 

STATUS

 

 

WHT.BAL

 

 

 

 

 

STATUS

ON

OFF

 

 

POWER

REC

 

 

1.In Standby or Stop mode, press the USER1 button for about 2 seconds while holding down the STATUS button.

The current time code generator data is displayed in enlarged display mode on the LCD screen. The hour digit starts blinking.

Aborting Preset Operation

While presetting, press the USER1 button while holding down the STATUS button.

Preset operation stops and the LCD screen returns to the original screen.

CAUTION

„Preset operation is terminated in the following.

TC DISPLAY switch is changed

CAM/VTR mode switch is changed

VTR operations are performed

„USER1, USER2, and USER3 presetting in the SWITCH MODE menus screen is not available when the Time Code Preset screen is displayed.

„The time code preset screen is displayed on the LCD screen or viewfinder. It will not be output from the VIDEO OUT terminal.