TDR6 Remote Command Listing (continued)

Mnemonics

Parameters/

DVB Defaults

 

Description

Response Values

 

 

 

 

 

 

 

 

 

 

MC DEFAULT RESTORE

where <string> = DVB,

 

Resets the TDR6 with the specified factory-default operating

<string>

Default1, Default2, and

 

 

configuration.

 

Default3

 

 

For more information on configurations, refer to the

 

 

 

 

configuration chapter.

 

 

 

 

Front panel equivalent: Config>Default>Restore

 

 

 

 

 

MC ETHERNET IP ADDRESS

<x.x.x.x> where each x

 

Sets the ethernet IP address for the TDR6. Example:

 

represents a decimal

 

 

192.200.9.201

 

number from 0 to 255

 

 

Front panel equivalent: Control>Network>Address

 

 

 

 

 

MC ETHERNET IP

<x.x.x.x> where each x

0.0.0.0

 

Sets the IP gateway address.

GATEWAY

represents a decimal

 

 

Front panel equivalent: Control>Network>Gateway

 

number from 0 to 255

 

 

 

 

 

 

 

 

MC ETHERNET IP MAC

Format:

 

Sets the Ethernet hardware address.

 

<xx:xx:xx:xx:xx:xx>

 

 

For example: 00:e0:74:00:02:cb

 

where xx is a

 

 

 

 

hexadecimal number

 

 

 

 

from 0 to f.

 

 

 

 

 

 

 

MC ETHERNET IP MASK

<x.x.x.x> where each x

255.255.255.0

Sets the IP address mask (IP subnet mask).

 

represents a decimal

 

 

Front panel equivalent: Control>Network>Mask

 

number from 0 to 255

 

 

 

 

 

 

 

 

MC HW OPTS

 

Query-only; displays the optional hardware installed on the

 

 

 

 

controller card.

 

 

 

 

Front panel equivalent: None

 

 

 

 

 

MC HW TYPE

 

Query-only; displays the type of decoder hardware.

 

 

 

 

Front panel equivalent: None

 

 

 

 

 

MC RS232 BAUD

1200, 2400, 4800, 9600,

38400

 

Sets the baud rate for the remote port.

 

19200, 38400

 

 

Front panel equivalent: Control>EIA-232>Baud

 

 

 

 

 

MC RS232 DATA

7, 8

8

 

Sets the data bits for the remote port.

 

 

 

 

Front panel equivalent: Control>EIA-232>Data Bits

 

 

 

 

 

MC RS232 HARDFLOW

On, Off

On

 

On: sets data flow to be controlled by hardware

 

 

 

 

Off: permits data flow to be controlled by hardware

 

 

 

 

Front panel equivalent: Control>EIA-232>Hard Flow

 

 

 

 

 

MC RS232 PARITY

None, Odd, Even

None

 

Sets the parity for the remote port.

 

 

 

 

Front panel equivalent: Control>EIA-232>Parity

 

 

 

 

 

MC RS232 SOFTFLOW

On, Off

Off

 

On: sets data flow to be controlled by software

 

 

 

 

Off: permits data flow to be controlled by software

 

 

 

 

Front panel equivalent: Control>EIA-232>Soft Flow

 

 

 

 

 

MC RS232 STOP

1, 2

1

 

Sets the stop bits for the remote port.

 

 

 

 

Front panel equivalent: Control>EIA-232>Stop Bits

 

 

 

 

 

MC SW

 

Query-only; displays the installed software version.

 

 

 

 

Front panel equivalent: Version

 

 

 

 

 

PGCA

 

When PGCA is entered, the TDR6 returns the following

 

 

 

 

conditional access information: mode, status, authorization,

 

 

 

 

and time-out

 

 

 

 

Front panel equivalent: None

 

 

 

 

 

PGCA AUTHORIZATION

Yes, No, N/A

 

Query-only; displays whether the originator of the service

 

 

 

 

has authorized your TDR6 to receive the selected service.

 

 

 

 

Front panel equivalent: Details>PGCA>Authorization

 

 

 

 

 

PGCA MODE

Auto

Auto

 

Sets the TDR6 to automatically receive authorized PGCA-

 

 

 

 

protected signals.

 

 

 

 

Front panel equivalent: None

 

 

 

 

 

PGCA STATUS

In_the_Clear,

 

Query-only; displays whether or not a signal is PGCA

 

PGCA_Enabled

 

 

protected.

 

 

 

 

Front panel equivalent: Details>PGCA>Status

 

 

 

 

 

Using a Remote Unit

01-0870-401B 01/03

43

Page 53
Image 53
JVC TDR6 MC Default Restore, MC Ethernet IP Address, Gateway, MC Ethernet IP MAC, MC Ethernet IP Mask, MC HW Opts, Mc Sw