Viterbi Bit Error – This register displays the number of channel bit errors

during the last measurement period. This register is used to estimate Eb/N0. If this register is zero, the Eb/N0 is 16.00 (no noise).

Any channel noise will cause this register to be greater than zero.

OFFSET – Use this command to confirm the location of the carrier. The definition of this query is:

(OFFSET = Actual RF – Programmed RF)

The units are in Hz.

Syntax – DMD.x OFFSET where x designates the demodulator that is the object of the command.

86

01-0870-401B 01/03

Demodulator Application Notes

Page 96
Image 96
JVC TDR6 installation and operation guide Offset = Actual RF Programmed RF