TMAC-6125The TMAC-6125 is the master controller module.

IN

ASI

OUT

TMAC-6125

PUSH

HERE

USER DATA B USER DATA A

FAULT RLY ETHERNET

REMOTE

TMAC-6125 Ports

The TMAC-6125 provides the following ports:

ASI IN – accepts the incoming ASI transport stream, with data rates up to

104 Mbps, on a female BNC connector, 75Ω impedance

ASI OUT – outputs a DVB/ASI compliant transport stream as a loop through of the input signal on a female BNC connector, 75Ω impedance. The output follows the input selected, i.e., ASI or RF.

The ASI Out port provides a pass through relay; if power is lost, the input is directly connected to the output.

USER DATA A and B – identical data ports that are independently configurable for either RS-422 synchronous/asynchronous communications up to 4.096 Mbps or RS-232 asynchronous communications up to 38.4 kbps

Both User Data ports are female, DB-9 connectors.

FAULT RLY (relay) – female RJ-11 connector that provides three connections to create a form-C status relay

The fault relay indicates a non-normal, or fault, condition when power is removed through a power failure, a power switch turned off, or an unplugged unit. The fault relay can also report user-programmable faults.

A fault condition is indicated by contact closure between pins one and three, and an open contact between pins one and six. Fault Relay pin assignments are provided in the port pinout appendix.

ETHERNET – female RJ-11 connector that provides remote control of the TRD6 over a network

REMOTE – female DB-9 connector that provides an RS-232 remote control interface to the TRD6

Remote control port pin assignments are provided in the port pinout appendix.

Connecting to a Remote Unit

The TMAC-6125 enables you to connect a remote unit to the TDR6 using the Remote port. A remote unit may be any device capable of asynchronous communications at RS-232 electrical levels including:

Personal computer with an asynchronous communications software application installed

ASCII computer terminal

To install a remote unit:

1.Connect a cable between the remote unit and the TDR6 remote control port.

2.Configure the communications software parameters of the remote unit to match the DVB default settings of the TDR6 remote control port.

8

01-0870-401B 01/03

Installing the TDR6

Page 18
Image 18
JVC TDR6 installation and operation guide TMAC-6125 Ports, Connecting to a Remote Unit