| Diagnostics and Troubleshooting | |
|
|
|
| |
Error | Error Code /Status | Possible Cause/Subsystem | Possible Solution | |
Code | Message | |||
|
| |||
|
|
|
| |
1101 | Density DMIN/DMAX points | Density points are invalid. | Reread density values on | |
| are invalid. |
| densitometer or make a new | |
|
|
| calibration print. | |
|
|
|
| |
1102 | Density data is not | Density data is invalid. | Reread density values on | |
| monotonic increasing. |
| densitometer or make a new | |
|
|
| calibration print. | |
|
|
|
| |
1103 | Exceeded maximum number | Density data is invalid. | Reread density values on | |
| of allowable data errors. |
| densitometer or make a new | |
|
|
| calibration print. | |
|
|
|
| |
1104 | Asymmetric Density | Density data is invalid. | Reread density values on | |
| Groupings are invalid. |
| densitometer or make a new | |
|
|
| calibration print. | |
|
|
|
| |
1201 | Unknown response from | The application received an | Verify that the baud rate of the | |
| densitometer. | unknown response from the | densitometer matches the | |
|
| densitometer during | applications configuration. | |
|
| initialization. |
| |
|
|
|
| |
1202 | Error:_error_from | Unexpected error was returned | Calibrate the densitometer. If the | |
| densitometer. | from the densitometer. | problem continues, check the | |
|
|
| manual for the densitometer. | |
|
|
|
| |
1203 | Error: Number of patches | Unable densities on densitometer. | Try adjusting frame counts or | |
| seen by densitometer is |
| reread the density patches on the | |
| incorrect. |
| densitometer. | |
|
|
|
| |
1300 | Values have not been loaded | Matrix file missing. | Create a new device. | |
|
|
|
| |
1301 | Data or Matrix files have not | Matrix file missing. | Create a new device. | |
| yet been loaded |
|
| |
|
|
|
| |
1302 | Data cannot be saved, must | Matrix file missing. | Create a new device. | |
| first apply the matrix |
|
| |
|
|
|
|
October 2002 |