A-61408 September 1995 3-9
F71 Omit Length Monitor on Next Document On/Off
Allows you to inhibit the length monitor on the next document
scanned. Normal length monitoring resumes with subsequent
documents. Enter 1 to enable or 0 to disable.
F72 Skew Monitor On/Off
Allows you to enable/disable the Skew Monitor which monitors for
an unacceptable skew. The degree of an unacceptable skew is
preprogrammed at installation. It can be either 5° or 10°.
Messages and/or confirmation tones indicate if the document is
shorter/longer than the predefined minimum/maximum.
F73 Latch Flag On/Off
Allows you to enable/disable the Latch Flag function. When
enabled, the Latch Flag function activates the Latch Flag bit in the
image header of documents entering the feeder to indicate the
scanned documents are of special interest. Enter 1 to enable or 0
to disable.
F74 Momentary Flag On/Off
Allows you to enable/disable the Momentary Flag function. When
enabled, the Momentary Flag function activates the Momentary
Flag bit in the image header of documents entering the feeder to
indicate the scanned documents are of special interest. Enter 1 to
enable or 0 to disable.
NOTE: The Momentary Flag will automatically disable after a
single document has been fed.
F75 Footswitch Confirmation Tone On/Off‡
Allows you to enable/disable the Confirmation Tone which is
issued whenever the footswitch is pressed and/or released. Enter
1 to enable or 0 to disable.
‡The Footswitch is an accessory.