B-4 A-61408 September 1995
Cleaning the Patch Reader The Patch Reader requires very little maintenance. Periodically
wipe the sensor head with a dry lint-free cloth.
IMPORTANT:
Do not remove the Cable Tie from the Patch
Reader.
Mounting Magnets
Cable Tie
Sensor Head
Mounting Magnets
Function Codes The following function codes are available if the Patch Reader 500
Accessory has been installed and the current application mode
allows use of the Patch Reader 500 Accessory.
F50 Patch Reader On/Off.
F53 Patch Reader Confirmation Tone On/Off.
F54 Omit Patch Reading on Next Document On/Off.
Used to disable patch reading for the next document only.
This will disable the Patch Reader if it has been previously
enabled.
F55 Patch Test (future function).
Refer to
Performing a Patch Test.
Follow these steps to use On/Off functions:
1. Press the F key.
2. Press the numeric key(s) which correspond to the Function
Code.
3. Press Enter.
NOTE: If the associated accessory is not installed, an Error
Message will be displayed.
4. Press the numeric key 1 to turn the function ON; or
press the numeric key 0 to turn the function OFF.
5. Press Enter. (Press C to cancel the function.)