A-61408 September 1995 B-3
Changing the Horizontal
Read Position The Horizontal Read Position is manually set by placing the
reader in one of the five reader positions on the mounting plate.
NOTE: The five patch reader positions are also indicated with a
patch mark on the label on the Feed Tray.
A3
A5
11 X 17"
A4
2.5"
8.5 X 11"
The Patch Reader is attached to the mounting plate by magnets.
To change the position of the Patch Reader, lift the reader off the
mounting plate and place it in one of the other four available
positions.
Perform the patch test function to make sure the patches printed
on the documents are aligned with the new reader position.
NOTE: The Patch Reader must be removed from the mounting
plate when raising the Horizontal Transport plate during
vacuuming or clearing document jams.
CAUTION: For safety reasons the movement of the Lower
Access Door is intentionally slowed with a two-
way rotary damper. Open and close the door
slowly.