6-4 A-61408 September 1995
4. Rotate the Feed Roller Cover Release Lever downward while
rotating the Feed Roller Cover up to expose the Feed Roller
and Separator Roller.
5. Press and hold the Gap Release Lever and remove all
jammed documents.
6. Rotate the Feed Roller Cover to its original position.
7. Lower and latch the Front Scan Module by lowering the
release bar.
8. Close the Lower Access Door.
Clearing a Jam in Area B Complete the following steps to clear the document path in Area
B. This area is comprised of the Horizontal Transport Plate, the
Lower Belt Module and the Lower Turn Roller areas.
1. Turn the power off.
2. Lift up the Lower Access Door.
CAUTION: For safety reasons the movement of the Lower
Access Door is intentionally slowed with a two-
way rotary damper. Open and close the door
slowly.