10. Make MOD SEQUENCE settings

a. Set SEQ COMMON parameters

As preparation before creating the actual sequence data, the SEQ COMMON parameters are used to specify things such as the maximum number of steps in the sequence and the playback method. Use the [+/YES] [–/NO] keys to set the values.

1Press the SELECT [11] key.

The LCD screen will show Page 18A: SEQ COMMON “Last Step.”

Specify the length (maximum number of steps) of the sequence that you wish to record, in the range of 1–16.

b. Specify sequence data for each step

Here’s how to select a program for which sequence is turned on, and record sequence data for each step.

1In Program Play mode, select a program for which sequence is turned on.

2Press the [EDIT] key.

You will enter LCD Edit mode.

3Press the SEQ EDIT/CH PARAM [SELECT] key to make the SEQ 1 LED light.

Introduction

panel

18A SEQ COMMON

Last Step: 16

2Press the CURSOR [®] key.

The LCD screen will show Page 18B: SEQ COMMON “Seq Type.”

Specify the direction in which the steps will play back.

18B SEQ COMMON

Seq Type:Forward

3Press the CURSOR [®] key.

The LCD screen will show Page 18C: SEQ COMMON “Run Mode.”

Specify the loop setting for sequence playback.

18C SEQ COMMON

Run Mode:Loop

4Press the CURSOR [®] key.

The LCD screen will show Page 18D: SEQ COMMON “Key Sync.”

Specify how the sequence will be reset when a note-on occurs.

18D SEQ COMMON

Key Sync:Timbre

5Press the CURSOR [®] key.

The LCD screen will show Page 18E: SEQ COMMON “Resolution.”

Specify the playback speed of the sequence relative to the internal clock.

18E SEQ COMMON

Resolution: 1/48

The LCD screen will show Page 19A: SEQ 1 “Knob.” For this example, we will assign FILTER “Cutoff” to SEQ1.

19A SEQ 1

Knob:None

4Press the [+/YES] key to set “Knob” to Cutoff.

19A SEQ 1

Knob:Cutoff

If you wish to assign a parameter to SEQ 2 or SEQ 3, use the [SELECT] key to select SEQ 2 or SEQ 3.

5Press the MOD SEQUENCE [ON/OFF] key.

The [ON/OFF] key LED will light, and the sequence will be turned on.

6Press and hold a note on the keyboard.

The program will sound, and the SELECT [1]–[16] keys will light consecutively.

7While listening to the sound, use the sixteen knobs located beside the SEQ EDIT LED to specify the sequence data for each step.

The sixteen knobs are normally used to edit program sounds (EG or LFO etc.), but when the [SELECT] key has selected a sequence, they are used to set and edit sequence data.

The numbers shown below each knob correspond to the sequence steps. Rotate the knob for the step you wish to set.

Front and rear

Connections

Playing

When you rotate a knob, the LCD screen will show 19C: SEQ 1 “Step Value.”

19C SEQ 1

Step[01]: +10

Step Number

Value

The value of each step is the amount of change relative to the parameter value that is currently written or set.