Noise emission levels

The following measurements were made in accordance with ISO 7779 and reported in conformance with ISO 9296.

1-meter average

 

sound pressure,

 

dBA

All models

Printing

55 dBA

 

 

Idling

34 dBA

 

 

Energy consumption

The following table documents the power consumption characteristics of the printer

Mode

Description

Power consumption

Printing

Printer is generating hard copy output

350 W

 

 

 

Power Saver

Printer is in energy saving mode

15 W for C520 and C522

 

 

17 W for C524

 

 

 

 

 

16 W for C522

 

 

18 W for C524 network models and C524 duplex network

 

 

model

 

 

 

The power consumption levels listed in the previous table represent time-averaged measurements. Instantaneous power draws may be substantially higher than the average.

Power regulation notice

Warning: Electrical surges can be very destructive to equipment connected to AC power sources. If you plan to operate your printer at a voltage exceeding the voltage range(s) in the following table, you must attach a suitably rated and certified power-regulating device (such as a voltage stabilizer or UPS device) to the printer power supply. Your warranty may not cover damages caused by power surges.

 

Maximum Voltage

Nominal Voltage Range

Range

100V–110V AC

90V–117V AC

 

 

110V–127V AC

99V–134V AC

 

 

220V–240V AC

198V–254V AC

 

 

Total energy usage

It is sometimes helpful to calculate the total printer energy usage. Since power consumption claims are provided in power units of Watts, the power consumption should be multiplied by the time the printer spends in each mode in order to calculate energy usage. The total printer energy usage is the sum of each mode's energy usage.