DEFINITY Enterprise Communications Server Release 8.2

Issue 1

Overview 555-233-002

April 2000

 

 

System Management Features

 

Alarm Assignments

88

 

 

 

 

 

 

 

 

Subnet Trunking

Modifies the number you dial so an AAR or ARS call can route over different trunk groups that may terminate in switches with different dial plans. Subnet Trunking inserts digits, deletes digits, pauses, and/or waits for dial tone in digit outpulsing, as required, so calls route:

To or through a remote switch

Over Tie trunks to a private network switch

Over CO trunks to the serving CO

Subnet Trunking is required on calls routing to or through a remote switch, regardless of the call’s destination.

Extension Number Portability

Gives you the ability to assign any extension to any system in a subnetwork. Stations can be moved across systems while retaining the original extension number, as long as the systems are part of a defined subnetwork. This feature is used in conjunction with Automatic Alternate Routing and Uniform Dial Plan.

Alarm Assignments

Alternate Operations Support System Alarm

Number

Allows you to establish a second number for the DEFINITY ECS to call when an alarmable event occurs. This feature is useful for alerting a second support organization, such as INADS or OneVision.

External Device Alarming

Allows you to assign analog ports to alarm interfaces for external devices. You can specify a port location, information to identify the external device, and the alarm level to report when a contact closure occurs.

Page 108
Image 108
Lucent Technologies 9400, 8400 manual Alarm Assignments, Subnet Trunking, Alternate Operations Support System Alarm Number