Pressure Systems, Inc.

Model 9116 User’s Manual

 

 

Command ‘c’— Sub-command Index 02: Stop Stream(s)

This sub-command is used to stop (or temporarily suspend) the delivery of any previously started host stream in a module, one at a time or all together, whether the stream was “continuous” or “limited.” The sub-command’s format is:

Command

c 02 st

 

 

‘c’ is the command letter

 

‘02’ is the sub-command index (‘ii’) for Stop Stream

 

st’ is the stream id digit (single stream 1, 2, or 3, or 0=all streams)

 

NOTE: all parameters are separated by a space.

 

 

Response

A

‘A’ is the acknowledge letter

 

 

 

Autonomous

command stops generation of autonomous packets from the requested

Packet

stream(s).

 

 

Description: This sub-command stops the current “run” of a particular specified host stream (st=1-3), or stops the current “run” of “all configured” host streams with a single command (st=0).

Any stopped stream may be resumed (i.e., restarted) with the Start Stream sub- command as long as that stream remains defined in the module and any limited sequence count has not yet expired. The Clear Stream sub-command may be used to undefine a stream. Any continuous stream or unexpired limited stream that is restarted continues generating new sequence numbers (i.e., at the count where it left off when stopped). However, the stream must be reconfigured with the Configure a Host Delivery Stream sub-command (00) before it restarts with sequence count =1. Any expired limited stream must be reconfigured to restart at all.

Example:

Stop all the streams configured in the previous example: “c 02 0

Read response:

“A”

Page 54

www.PressureSystems.com

Page 63
Image 63
Measurement Specialties 9116 user manual Command ‘c’- Sub-command Index 02 Stop Streams, Command 02 st