Pressure Systems, Inc. | Model 9116 User’s Manual |
|
|
●High accuracy - Model 9116 pressure scanners are capable of accuracies up to ±0.05%. Accuracy is maintained through use of
●Low thermal errors - each internal transducer contains an individual temperature sensor and thermal calibration data for internal use by software correction algorithms. Thermal errors are reduced as low as ±0.001%FS/ºC over the calibrated temperature span.
●
●Ease of transducer replacement - factory calibrated transducer assemblies may be stocked and rapidly replaced in the field. Storage of thermal coefficients within the transducer allows for ‘plug and play’ transducer replacement.
●Ease of calibration - each Model 9116 module contains a pneumatic calibration manifold and software commands to automatically perform
●Ease of use - modules have simple command sets and provide engineering units output. They may interface directly to a desktop or laptop computer or they may be interconnected into a large network controlled by many types of host computers.
●Connectivity - use of
1.2.1Differences Between Models 9016 and 9116
The all new electronics of the Model 9116 reduces data acquisition noise and capture latency, while actually improving channel settling time and boosting data throughput. Additionally, the Ethernet interface has been upgraded to 10BaseT/100BaseT with half and full duplex capabilities to provide significant flexibility in network configuration. The Ethernet interface is completely
The firmware in the Model 9116 implements the Model 9016 command set further simplifying use with existing systems. In fact, the Model 9116 can be configured to report its identity as a Model 9016 to ensure compatibility with system software that is sensitive to the reported model type.
Page 3 | www.PressureSystems.com |