Pressure Systems, Inc.Model 9116 User’s Manual

 

cc

 

 

Transducer Coefficients Description

 

 

Datum

 

 

 

 

 

 

Type

 

 

 

 

 

 

 

 

 

 

33

 

Temperature 6 Temperature Output voltage at 0 psi

 

FLOAT

 

 

 

 

 

 

34

 

 

(reserved) Temperature 7 Temperature Output voltage at 0 psi

 

FLOAT

 

 

 

 

 

 

 

35

 

 

Temp Vs Pressure Correction coefficient

(t0)

 

FLOAT

 

 

 

 

 

 

 

36

 

 

Temp Vs Pressure Correction coefficient

(t1)

 

FLOAT

 

 

 

 

 

 

 

37

 

 

Temp Vs Pressure Correction coefficient

(t2)

 

FLOAT

 

 

 

 

 

 

 

38

 

 

Temp Vs Pressure Correction coefficient

(t3)

 

FLOAT

 

 

 

 

 

 

 

 

 

4D

 

Pressure Voltage Gain Index

 

 

 

INTEGER

 

 

 

 

 

 

 

 

 

4E

 

Temperature Voltage Gain Index

 

 

 

INTEGER

 

 

 

 

 

 

 

 

5F

Current Calculated Pressure (PSI)

 

 

 

FLOAT

 

 

 

 

 

 

 

 

 

 

The User Defined Date field (cc=07) is also a 32-bit integer which may be encoded in a similar manner. Possible uses are to indicate the date of last user zero and/or span calibration or possibly the date of next required calibration. If this optional field is used, the user is responsible for correctly encoding the date into the appropriate 32-bit integer value. Any modifications of this field (using the Download Internal Coefficients (‘v’) command) will result in the new value automatically being entered to transducer non-volatile memory.

The Date of Factory Calibration field (cc=08) identifies the date of factory calibration for the DH200 transducer (9116). It is stored internally as a 32-bit integer whose value (viewed as a decimal number) is in the format of yymmdd (year, month, day).

A special single Other Coefficients array is selected with array index aa=11 (hex). All the valid coefficient indexes (for this array only) are listed in the following table:

 

cc

 

 

Other Coefficients Description

 

 

Datum

 

 

 

 

 

 

Type

 

 

 

 

 

 

 

 

 

00

 

reserved - EU conversion offset term

 

FLOAT

 

 

 

 

 

 

01

 

 

EU Pressure Conversion scaler (default=1.0)

 

FLOAT

 

 

 

 

 

02

 

Reserved - EU conversion Non-Linearity term

 

FLOAT

 

 

 

 

 

03

 

Reserved-Reference Voltage value

 

FLOAT

 

 

 

 

 

 

 

 

 

Page 78

www.PressureSystems.com

Page 87
Image 87
Measurement Specialties 9116 Transducer Coefficients Description Datum Type, Other Coefficients Description Datum Type