Model Intelligent Pressure Scanner User’s Manual
Revision Revision History Print Date
Table of Contents
Table of Contents
Calibration
Service 102
Appendices
Troubleshooting Guide 118
Start-up Software 124
Preface
Technical Support
Our Warranty
Merchandise Return Procedures
Our Company
Website and E-Mail Our Firmware Our Publication Disclaimer
Chapter General Information Introduction
Model 9116 Intelligent Pressure Scanner
Description of the Instrument
Differences Between Models 9016
Set Module type alias w3200
Set Hardware Trigger Mode w320x
Manifolds and Pressure Connections
Firmware Updates/Boot Loader
Options
Pressure Ranges
Communication Interfaces
Environment
Chapter Installation and Set Up Unpacking and Inspection
Safety Considerations
Preparation for Use
Power Pin Assignments
Power
Ethernet Host Port Hookup
Mounting and Module Dimensions
Ethernet Host Port Connector Pins
Network Communications Hookup
Pressure Systems, Inc Model 9116 User’s Manual
Pressure Systems, Inc Model 9116 User’s Manual
Ethernet Network Topology
Pressure Connections
Diagnostic Port Hookup
Pressure Systems, Inc Model 9116 User’s Manual
Purge Mode Inputs
CAL Mode Inputs
Supply Air
Leak Mode Inputs
Case Grounding
Trigger Input Signal
Power Up Checks and Self-Diagnostics
1.1 TCP/UDP/IP Protocols
Chapter Programming and Operation Commands & Responses
Introduction
General Command Format
Commands
Position Field
Command Field
Format Field
Datum Fields
An Acknowledge with Data response, or
Responses
Interpreting Engineering Units Output
Functional Command Overview
Interpreting Offset Values Re-zero Calibration Adjustment
Interpreting Gain Values Span Calibration Adjustment
Module Data Acquisition
Startup Initialization
Pressure Systems, Inc Model 9116 User’s Manual
Delivery of Acquired Data To Host
Other Functions
Network Query and Control Functions
Type Command ID Command Functions
Detailed Command Description Reference
Example
Power UP Clear Command ‘A’
Command
Response
Reset Command ‘B’
Command Ii dddd
CONFIGURE/CONTROL MULTI-POINT Calibration Command ‘C’
Pppp npts ord avg
‘ 00’ is the sub-command index ii for Configure & Start
00 F 3 1 32 Read response a
Response Pppp.pppp pppp.pppp
Pnt pppp.pppp
01 1 -2.5 C 01 2 0.0 C 01 3
‘ 02’ is the sub-command index ii for Calculate & Apply
Example
‘ 03’ is the sub-command index ii for Abort
Dddd.. dddd
Read Transducer Voltages Command ‘V’
Vppppf
Response Description
V11110
Response g.gggg .. g.gggg
Calculate and SET Gains Command ‘Z’
Zpppp
000212 1.000269 1.000437 1.000145
Z00F8
Appppf
Read Transducer A/D Counts Command ‘a’
32767.000000 -32700.000000 10.000000
A11110
Aaaabbbbcccc .. rrrr
Read HIGH-SPEED Data Command ‘b’
Aaaabbbbcccc..rrrr
Packet
DEFINE/CONTROL Autonomous Host Streams Command ‘c’
Ii dddd Command
Autonomous
Pressure Systems, Inc Model 9116 User’s Manual
St pppp sync per f num
‘sync’ Meaning of ‘per’
Pressure Systems, Inc Model 9116 User’s Manual
00 1 000F 0 1 7 0 c 00 2 00F0 0 2 7 0 c 00 3 FF00 0 4 7
Command 01 st
Command ‘c’- Sub-command Index 01 Start Streams
Example
Command 02 st
Command ‘c’- Sub-command Index 02 Stop Streams
02 0 c 03 3 c 01
Command ‘c’- Sub-command Index 03 Clear Streams
Command 03 st
St pppp sync per f num pro remport ipaddr bbbb
Command ‘c’ Sub-command Index 04 Return Stream Information
Command 04 st
Ffff 0 20 7 32000 1 7002
St bbbb
Command ‘c’ Sub-command Index 05 Select Data in a Stream
Bbbb hex
05 1 0012 Read response
St pro remport ipaddr
‘ 06’ is the sub-command index ii for Select Protocol
06 0 0 Read response
06 0 1 7500 Read response
Gggg .. g.gggg
Calculate and SET Offsets Command ‘h’
Hpppp
0010 0.0020 0.0015
HF000
Mppppf
Read Temperature Counts Command ‘m’
20692.000000 19783.000000 19204.000000
M11110
Nppppf
Read Temperature Voltages Command ‘n’
53013 0.541698 0.503633
N11110
Firmware Version, as hex value
Read Module Status Command ‘q’
Returned value ‘w’ set Digit hex or other decimal Index
Temperature Range, as a hex value
Auto UDP Broadcast@Reset, as hex state
Hardware trigger mode
Q07
Rppppf
Read HIGH-PRECISION Data Command ‘r’
R11110
Response Dddd.. dddd
Read Transducer Temperature Command ‘t’
Tppppf
T11110
Converts each internal value from Max. char
Read Internal Coefficients Command ‘u’
Ufaacc-cc
Dynamic EU Conversion coefficient c2
Span Cal Adjustment gain term
Dynamic EU Conversion coefficient c0
Dynamic EU Conversion coefficient c1
Other Coefficients Description Datum Type
EU Pressure Conversion scaler default=1.0
Transducer Coefficients Description Datum Type
Example
Converts each internal value from
Download Internal Coefficients Command ‘v’
Vfaacc-ccdddd..dddd
Datum Type
Other Coefficients Description
V01101 6.894757 Response returned is a
V00800-01 0.000 1.000 Response returned is a
Wiidd eeee
SET/DO Operating OPTIONS/FUNCTIONS Command ‘w’
Calculate and Set Offsets ‘h’ command default
Disable Automatic Shifting of Calibration Valve in ‘h’
Enable Host Response/Stream Back-Off Delay specified
Disable periodic Thermal Coefficient Update task
Set Number of A/D Samples to Average, default =
Set Cal Valves to RUN or CAL/RE-ZERO Position default
Description ‘q’ read Index
W0C01
Position
W1200
Parameter Meaning
Network Query UDP/IP Command ‘psi9000’
Psi9000
Psireboot 00-E0-8D-00-00-01 Response None
RE-BOOT Module UDP/IP Command ‘psireboot’
Command Psireboot ethadr
Psirarp 00-E0-8D-00-00-01 Response None
Command Psirarp ethadr
PTV
Chapter Calibration Introduction
Figures 4.1 Pneumatic Diagrams of the Calibration Manifold
Re-zero Calibration Valve Control
Re-zero Calibration
Section
Description Model 9116 Command
Span Calibration
Re-zero Calibration Summary
Span Calibration Valve Control
Zffff
Span Calibration Summary
Description Model 9116 Command
Multi-Point Calibration Valve Control
Integrated Multi-Point Calibration Adjustment
Multi-Point Calibration Summary
Description Model Command
Coefficient Storage
Line Pressure Precautions
Exploded View of Model
Chapter Service Maintenance
Pressure Systems, Inc Model 9116 User’s Manual
Component Cross Reference Section
Common Maintenance
Electronic Circuit Board Replacement
Module Disassembly
3.1 PC-327 Analog Board
3.2 PC-322/323 Main Board/PowerPC Daughter Board Assembly
PC-322/323 Assembly
PC-323 Daughter Board Removed froom PC-322
Remove and Replace PC-323 Daughter board on PC-322 Main PCB
Top View of DH200
Replacement of Transducers
PC-322 Board
Calibration Valve Solenoid Replacement
Solenoids in Module
Replacement of O-Rings
DH200 Transducer O-Ring Replacement
6.1 DH200 Pressure Transducer O-Ring Replacement
Tubing Plate O-Ring Replacement
Adapter Plate O-Ring Replacement
Calibration Manifold Piston O-Ring Replacement
Solenoid Valve O-Ring Replacement
Upgrading Firmware Via Host TCP/IP Port
Upgrading Module Firmware
Checking Module Power-Up Sequence
Module IP Address Assignment
Checking Module TCP/IP Communications
Pressure Systems, Inc Model 9116 User’s Manual
Verifying Host TCP/IP Communications
Zero and Gain Calibration Troubleshooting
User Software
Chapter Start-up Software Introduction
UDP/IP
Appendix a All Commands Quick Reference
Undefined Command Received
Appendix B Model 9116 Response Error Codes
Appendix C Cable Diagrams
Pressure Systems, Inc Model 9116 User’s Manual
Appendix D Mounting Dimensions
Psi 10 Water Column Psig Psi 20 Water Column Psid Psia
Appendix E Model 9116 Range Codes
Psid Psig Psia
Model Purpose
Appendix F
NetScanner System Products
Bit Value If Set Position Binary Number
Appendix G Binary Bit Map
Headquarters/Factory