Mitsubishi Electronics SDP-ECO 1630 III Laser menu, Remaining amount of plate, Resolution setting

Models: SDP-ECO 1630 III

1 83
Download 83 pages 36.16 Kb
Page 50
Image 50

SDP-Eco1630 III USERS MANUAL

Remaining amount of plate

The remaining amount of plate should be set in meter units when you use a new plate.

The initial setting value is 0 meter.

The remaining amount of plate is shown in 1 meter increments (0 to 75 meters) in the remote mode display

The remaining amount value is calculated by subtracting the exposed plate length from the plate length set by the operator. The plate length for preliminary feeding is also subtracted.

However, the accuracy of the remaining length measurement is not guaranteed. Please regard this value simply as a reference guide.

6.2 Laser menu

The laser menu contains a command to set the laser for exposing the current plate.

Sample panel display

Plate type

Resolution

Laser value

F 1 7 5

( 1 2 )

2 0 0

 

 

 

Resolution setting

(12)......1200dpi

(15)......1500dpi

(18)......1800dpi

(24)......2400dpi

Laser setting

From the panel, you can set the exposure laser for each resolution to be used with the current plate.

1)Set the resolution and laser value.

2)If necessary, expose a trial sheet to adjust the laser.

- 42 -

Page 50
Image 50
Mitsubishi Electronics SDP-ECO 1630 III manual Laser menu, Remaining amount of plate, Resolution setting, Laser setting